IF5 Fixed Reader User's Manual
Chapter 3 — Developing and Using RFID Applications
2 (Optional) Change settings for the performance test:
• Enter a value for the length of each read cycle in the Cycle
length field. The default is two seconds.
• Enter a value for the number of read cycles in the Number
of Cycles field. The default is five cycles.
3 Click Start test. The performance test begins and tag
information appears in a table in the browser window.
The test returns this data:
• Tag ID: Tag ID for each identified tag. This field appears
only if you have selected ISO6BG1 as the supported tag
type.
• # Times read: Number of times each tag was read during
the test. This field appears only if you have selected
ISO6BG1 as the supported tag type.
• Total tags read: Total number of times all tags were read
during the test