Element
pollingInterval
tagID.type
tagID.address
tagID.length
logFile
output.use
output.mode.inactive
output.mode.
readingNoTags
IF5 Fixed Reader User's Manual
Appendix B — Configuring and Using the SAP Device Controller
Default
Description
0
(Optional) Sets the interval in ms between READ
commands sent by the reader. The polling loop can run
continuously, or can be started by a trigger and run for
a period set by trigger.time.
EPC
Defines the type of tag to be read:
EPC: EPC tag ID stored on the tag in the standard
location for that tag type.
ISO: For UCODE 1.19 tags, this is the ISO tag ID,
stored in the standard ISO tag ID location. For EPC
Class 1 Gen 2 tags, the TID field is returned as the tag
ID.
CUSTOM: ID is stored in a customer-defined area in
user memory on the tag. The tagID.address and
tagID.length properties determine where the ID is
stored on the the tag.
0
(Optional) Defines the memory address where the tag
ID is stored. This can be used when some ID other
than the manufacturer-set tag ID is desired. Set
tagID.type to CUSTOM to define tagID.address.
Use an integer to specify the memory address for ISO
tag types.
For EPC Class 1 Gen 2 tags, specify the address as
<memory bank>:<memory address>. For example,
specify "3:15" to choose memory bank 3 at address 15.
8
(Optional) Sets the length of the tag ID. Set tagID.type
to CUSTOM to define tagID.length.
-
(Optional) Specifies the file name that BRI logs should
be written to. If not set, no BRI logging occurs.
0
(Optional) Set to 1 to use GPIO output ports to
indicate the operation the reader is performing.
0
(Optional) When output.use=1, the outputs are set to
this value when the reader is inactive.
0
(Optional) When output.use=1, the output ports are
set to this value when the reader is reading and no tags
are found in the field.
149