Appendix B — Configuring and Using the SAP Device Controller

Options for LowPassFilter

Options for SelectedFieldEnricher

162
RemoveTags
If set to true, tags that disappear are removed from the list (except
the pallet). The risk of using this setting is that tags may be
reported as "disappeared" due to a misread, although they are still
in the field. Default is false.
InCommand
The command used to be used in the PML Core message. This is
a redefinition of the the "InCommand" parameter of the parent
SendDataProcessor class. Default is PACK.
TimerInterval
The time (in milliseconds) to wait before a "disappeared" event is
sent on. If an "appeared" event appears within this time interval,
no events are sent on. Default is 100.
AddField
Adds the logical field name of a data field that should be read.
This option can be repeated multiple times.
ClearFields
Clears the list of data fields that should be read. Not necessary in
complete configuration files.
MappingTable
The name of the mapping table for converting logical field names
into physical memory addresses on the tag. The mapping tables
are defined in the global field map.
RemoveField
Removes a logical field name from the data fields that should be
read. This option can be repeated multiple times. Not necessary
in complete configuration files.
Retries
The number of read retries performed if there was an error
reading a data field.