Chapter 3 — Developing and Using RFID Applications

Read Tries

Sets the maximum number of times the read algorithm is
executed before a response is returned to a Read command.
In practice, this is the number of times an identified tag is read
until the Read is successful. Valid range is 1 to 254 (default is 3).
This setting is equivalent to the RDTRIES BRI attribute.

Write Tries

Sets the maximum number of times the write algorithm is
executed before a response is returned to a Write command.
In practice, this is the number of times an identified tag is written
to until the Write is successful. Valid range is 1 to 254 (default is
3).
This setting is equivalent to the WRTRIES BRI attribute.

Lock Tries

Sets the maximum number of times the lock algorithm is
executed before a response is returned to a Lock command. Valid
range is 1 to 254 (default is 3).
This setting is equivalent to the LOCKTRIES BRI attribute.

Field Separator

Sets the space character to be used for separating fields in tag
data. Choose from space ( ), comma (,), colon (:), semicolon (;),
tab, caret (^), or tilde (~). Default is space.
This setting is equivalent to the FIELDSEP BRI attribute.

ID Report

Enables or disables tag ID reporting after a Read, Write, or Lock
command is executed:
• For ISO tags, the tag identifier corresponds to TAGID.
• For EPC tags, the identifier corresponds to EPCID.
Check the check box to enable tag ID reporting. This setting is
equivalent to the IDREPORT BRI attribute, and is enabled by
default.
IF61 Fixed Reader User's Manual
65