Intermec IF5 User Manual page 166

Fixed reader
Hide thumbs Also See for IF5:
Table of Contents

Advertisement

Appendix B — Configuring and Using the SAP Device Controller
Element
output.mode.reading
output.mode.writing
trigger.mode
trigger.value
trigger.mask
trigger.time
idTries
readTries
writeTries
selectTries
unselectTries
lockTries
initTries
antennaTries
antennas
tagType
150
Default
Description
0
(Optional) When output.use=1, the output ports are
set to this value when the reader is reading and tags are
found.
0
(Optional) When output.use=1, the output ports are
set to this value when the reader is writing to a tag.
NONE
(Optional) Sets GPIO state that fires a trigger
operation:
NONE: No triggers are used.
AND: A single trigger is used. To fire, the value on the
GPIO ports bitwise ANDed with trigger.mask must
equal trigger.value.
OR: Not supported by this release.
1
(Optional) Sets the value that must be on the GPIO
ports to fire a trigger.
15
(Optional) Sets the mask used for the GPIO ports
value.
1000
(Optional) Sets the time in ms during which the reader
tries to find tags after a trigger is fired. Also sets the time
that passes before the trigger fires again.
2
(Optional) Sets the ID tries.
3
(Optional) Sets the Read tries.
3
(Optional) Sets the Write tries.
1
(Optional) Sets the Select tries.
1
(Optional) Sets the Unselect tries.
254
(Optional) Sets the Lock tries.
1
(Optional) Sets the Initialization tries.
3
(Optional) Sets the Antenna tries.
1,2,3,4
(Optional) Sets the antennas to be used and the firing
sequence for those antennas.
UCODE119 (Optional) Defines the type of tags to be read:
G1: ISO Class 1 Gen 1 tags
G2: ISO Class 1 Gen 2 tags
UCODE119: Phillips v1.19 tags
EPCC1G2: EPC Class 1 Gen 2 tags
MIXED: Mixed groups of tags