N O T E
The 86146B specifications are for the 50 µm internal path only.
Table 7-1. Wavelength Specifications
Wavelength Range
a
Reproducibility
1 min
Span Range
Accuracy
After calibration with internal calibration source and
with enhanced wavelength calibration on for specified
,
,
range
a
b
c
1480 to 1570 nm
1570 to 1620 nm
After calibration with external reference source(s)
±
10 nm of calibration reference point(s)
After user calibration over full wavelength range
600 nm - 1700 nm
a,d,
Absolute Accuracy
e
Tuning Repeatability (
1 min)
a,b,d
Span Linearity
1525 nm - 1570 nm
for spans <40 nm
a. With applied input fiber 9/125µm
b. Typical
c. At room temperature
°
d. Temperature range 20 to 30
e. Factory calibration on a 2-year cycle
Table 7-2. Resolution Bandwidth (RBW) Specifications
Resolution Bandwidth (RBW)
,
FWHM (3 dB Bandwidth)
b
c
a, b, c
a,
d
a
C
Agilent 86142B, 86143B,
86145B
0.06, 0.1, 0.2, 0.5, 1, 2, 5,
10 nm
Specifications and Regulatory Information
600 nm to 1700 nm
±
0.002 nm
0.2 nm to full range and zero span
±
0.01 nm
±
0.025 nm
±
0.01 nm
±
0.2 nm
±0.5 nm
±0.002 nm
±
0.01 nm
±
0.02 nm
Agilent 86143B w/Opt
Agilent 86146B
a
025
0.06, 0.07, 0.1, 0.14, 0.2,
0.07, 0.1, 0.2, 0.5, 1,
0.33, 0.5, 1, 2, 5, 10 nm
Specifications
2, 5, 10 nm
7-5