Agilent Technologies 8614 B Series User Manual page 209

Optical spectrum analyzer
Table of Contents

Advertisement

Table 5-6. OSA Warnings (7 of 12)
Error Number
Error Description [description/explanation/examples]
5066
desc = "Error in Enhanced Wavelength Calibration"
help = "Enhanced Wavelength Calibration failed. Check OSA system. If the error
persists, contact the Agilent Service Center.
5067
desc = "OSNR marker not allowed."
help = "A request was made to enable the OSNR marker readout. The readout
cannot be enabled for one of the following reasons: OSNR markers cannot be used
on traces which have X axis units other than meters. This typically occurs in zero
span where the X axis units are seconds. OSNR marks cannot be used on traces
which have Y axis units other than power. this typically happens when trace math is
on and the trace Y axis represents a ratio."
5068
desc = "The configured SHARE does not exist."
help = "A request was made to a remote file or printer share that does not exist or
cannot be found."
5069
desc = "The configured SHARE cannot be accessed."
help = "A request was made to a remote file or printer share that cannot be
accessed using the configured USER, PASSWORD, or DOMAIN/WORKGROUP."
5070
desc = "Trajectory add failed."
help = "The trajectory add procedure failed. This usually occurs when the trajectory
table is full or the computed trajectory table is invalid. The correct this problem, try
AUTO ALIGN PRESET and the AUTO ALIGN & ADD TO TRAJECTORY procedure
again. If the error persists, contact the Agilent Service Center.
6700
desc = "Math expression input parameter undefined."
help = "A math expression could not be evaluated because one or more input
arguments are undefined. Please check the spelling of all input arguments."
6701
desc = "Math expression input parameter has error."
help = "A math expression could not be evaluated because an error is present on
one or more of the input arguments. The error must be cleared before the
expression can be evaluated."
6702
desc = "Math expression parameter has zero length."
help = "A math expression could not be evaluated because one or more input
arguments has a zero length. This is often caused when the subset of a trace
contains no points such as when advanced line marker functions are turned on and
the line markers are too close together. It can also be caused when peak/pit
searches find no peaks or pits."
Status Listings
OSA Warnings
5-23

Advertisement

Table of Contents
loading

Table of Contents