Access Management

Local Console Access

Function
DisableLocalConsole(
<SID>)
EnableLocalConsole(
<SID>)

Remote Port Access

Function
LockClientLogin(<SID
>)
UnlockClientLogin(<S
ID>)
SetPortAccessMode(
1,<access mode>)

Checking Access Control Box Pushbutton

Function
GetLocalPushButtonS
tatus(<SID>)
50
Description
Disables local console access.
Enables local console access.
Description
Prohibits remote access to the remote
port.
Returned value of '0' = Success
Allows remote access to the remote
port.
Returned value of '0' = Success
Sets the access mode for the remote
port.
0 = full access
1 = view only
2 = denied access
Description
Shall be used in conjunction with the
ATEN Access Control Box, checks the
current pushbutton status.
0 = released
1 = pressed
Example
DisableLocalConsole(
4)
EnableLocalConsole(
4)
Example
LockClientLogin(4)
UnlockClientLogin(4)
SetPortAccessMode(
1,0)
Example
GetLocalPushButtonS
tatus(4)