5. From the Network tab, select Set IP address manually and enter the
following:
IP Address — sets the IP address for the RCM/KE devices. Key in a
valid unique IP address.
Note: See Default IP Addresses, page 47, for the preconfigured
factory-default settings.
Subnet Mask — sets the subnet mask for the RCM/KE devices. Key in
a valid subnet mask value.
Note: The default setting is 255.255.255.0
Default Gateway — sets the default gateway for the RCM/KE devices.
Key in a valid default gateway.
6. Click Save.
Exit OSD
To exit the OSD, press [Esc] on the keyboard, click Logout; tap the [Scroll
Lock] key twice; or return to the OSD main page and press the front panel OSD
pushbutton (receiver only).
At this point the receiver can connect to the transmitter to access the PC /
workstation remotely (see OSD Matrix Mode, page 73 for instructions).
Default IP Addresses
The preconfigured factory-default IP addresses for the RCM/KE series devices
are as follows:
transmitters – 192.168.0.61
receivers – 192.168.0.60
Chapter 2. Hardware Setup
47