ATEN PE6108AV User Manual

ATEN PE6108AV User Manual

8-outlets eco pdu
Table of Contents

Advertisement

Quick Links

PE6108AV / PE6208AV / PE8208AV
8-Outlets eco PDU
User Manual
www.aten.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PE6108AV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATEN PE6108AV

  • Page 1 PE6108AV / PE6208AV / PE8208AV 8-Outlets eco PDU User Manual www.aten.com...
  • Page 2: Emc Information

    PE6108AV / PE6208AV / PE8208AV User Manual EMC Information FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 3: User Information

    ATEN is not liable for any loss or damage.
  • Page 4: Pe Device Safety Notice

    PE6108AV / PE6208AV / PE8208AV User Manual PE Device Safety Notice Set the maximum permissible breaker protection in the building circuitry to the current rating specified on the rating plate. Observe all national regulations and safety codes as well as deviations for breakers.
  • Page 5: Package Contents

    Copyright © 201 ATEN® International Co., Ltd. Date Published: 2018-09-11 NRGence and the NRGence logo are registered trademarks of ATEN International Co., Ltd. All rights reserved. All other brand names and trademarks are the registered property of their respective owners.
  • Page 6: Table Of Contents

    Components ..........6 PE6108AV / PE6208AV / PE8208AV Front View ....6 PE6108AV / PE6208AV / PE8208AV Rear View (exclude PE6208AVX) .
  • Page 7 eco PDU PE Series User Manual First Time Setup Operation Methods ......... . 23 Browser .
  • Page 8 PE6108AV / PE6208AV / PE8208AV User Manual Switch Outlet Status ........73 Read Power Value .
  • Page 9: About This Manual

    eco PDU PE Series User Manual About This Manual This User Manual is provided to help you get the most from your eco PDU system. It covers all aspects of installation, configuration and operation. An overview of the information found in the manual is provided below. Chapter 1, Introduction, introduces you to the eco PDU system.
  • Page 10: Conventions

    PE6108AV / PE6208AV / PE8208AV User Manual Conventions This manual uses the following conventions: Monospaced Indicates text that you should key in. Indicates keys you should press. For example, [Enter] means to press the Enter key. If keys need to be chorded, they appear together in the same bracket with a plus sign between them: [Ctrl+Alt].
  • Page 11: Chapter 1 Introduction

    ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage The NRGence PE6108AV / PE6208AV / PE8208AV eco PDUs are intelligent PDUs that contain 8 AC outlets with a detachable front panel for convenient rack mounting and are available in various IEC or NEMA socket configurations.
  • Page 12 PE6108AV / PE6208AV / PE8208AV User Manual This series of ATEN eco PDUs have threshold alerts that can sound an alarm and send SNMP trap or e-mail alerts when a threshold is exceeded. This feature provides a faster response time to recover servers and other devices when the outlets surpass thresholds set by you.
  • Page 13: Features

    Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS Support: eco Sensors, Browser (IE, Firefox, Chrome, Safari) Additional functions available with ATEN VanCryst Pro A/V & VK Control System installations Metering Bank level power metering and monitoring (PE6208AV); or PDU and outlet level power metering and monitoring (PE8208AV) Environment monitoring –...
  • Page 14: Requirements

    PE6108AV / PE6208AV / PE8208AV User Manual Requirements Browsers accessing the eco PDU unit must support SSL 128 bit encryption. For cold booting of attached computers, the computer's BIOS must support Wake on LAN or System after AC Back. For Safe Shutdown: The computer must be running Windows (Windows 2000 or higher) or Linux.
  • Page 15: Optional Accessories

    Sensors can be managed via the eco PDU’s built-in graphical user interface (GUI) or with the NRGence eco Sensors software that can be downloaded from the ATEN website. The download link can be found on the software CD provided with the eco PDU package.
  • Page 16: Components

    PE6108AV / PE6208AV / PE8208AV User Manual Components PE6108AV / PE6208AV / PE8208AV Front View Item Description Port LED The Port LEDs provide status information about their corresponding AC outlet ports. There is one pair of LEDs for each port. The one on the left is the Local LED; the one on the right is...
  • Page 17 Chapter 1. Introduction Item Description Status LED The current (in amps), IP address or Holiday Mode status displays here. You can switch between the Current and IP status using the Current / IP Switch (see item 7, below). When the Current status is displayed the Current LED (see above) lights RED.
  • Page 18: Pe6108Av / Pe6208Av / Pe8208Av Rear View (Exclude Pe6208Avx)

    The power cable from the AC source plugs in here. Socket RS-232 This port can be used to attach to a computer for local power on/ Port off/reboot control. LAN Port The Cat 5e cable that connects the PE6108AV / PE6208AV / PE8208AV to the Internet plugs in here.
  • Page 19: Pe6208Avx Rear View

    Chapter 1. Introduction PE6208AVX Rear View Item Description Reset Press and release to reboot the PDU. This switch is recessed and Switch must be pushed with a thin object, such as the end of a paper clip, or a ballpoint pen. Sensor Two Sensor LEDs light GREEN when a sensor is connected to the LEDs...
  • Page 20 PE6108AV / PE6208AV / PE8208AV User Manual This Page Intentionally Left Blank...
  • Page 21: Chapter 2. Hardware Setup

    To place or stack the PE6108AV / PE6208AV / PE8208AV, remove the backing material from the bottom of the rubber feet that came with this...
  • Page 22 PE6108AV / PE6208AV / PE8208AV User Manual Note: To ensure adequate ventilation, allow at least 5.1 cm on each side, and 12.7cm at the back for power cord and cable clearance.
  • Page 23: Rack Mounting

    Chapter 2. Hardware Setup Rack Mounting The PE6108AV / PE6208AV / PE8208AV can be installed in most standard 19" (1U) racks. To rack mount the unit do the following: 1. Separate the front and rear modules by removing the four module...
  • Page 24 PE6108AV / PE6208AV / PE8208AV User Manual 3. There is an RJ-45 port on the front panel and rear module used to connect the two units. A standard Ethernet cable can be used to extend the front panel and rear module farther apart.
  • Page 25: Power Cord Installation (Pe6208Avx)

    If you are not a qualified electrician (having appropriate licensing and insurance) - STOP NOW. ATEN is not responsible for any damages to equipment or loss of data due to improper installation.
  • Page 26: Installation

    PE6108AV / PE6208AV / PE8208AV User Manual Installation These instructions must be performed by a licensed electrician. 1. Remove the six screws from the cover covering the terminal block compartment. 2. Remove the cover from the compartment and loosen the cable gland by turning the gland nut counter-clockwise (use a dedicated spanner if required).
  • Page 27 Chapter 2. Hardware Setup 5. Add wire ferrules to the wires. 6. Slide the power cord into the compartment through the cable gland and inner ring as shown below: 7. Open the gates of the power terminal block by loosening the screws on the top using a screwdriver.
  • Page 28 PE6108AV / PE6208AV / PE8208AV User Manual 9. Replace the cover and tighten the six screws to secure it to the unit.
  • Page 29: Installation

    4. If you choose to use a serial device for control, connect its serial port to the PE6108AV / PE6208AV / PE8208AV's RS-232 port. 5. Connect the eco PDU's power cord to an AC power source. Note: We strongly advise that you do not plug the eco PDU into a multi socket extension cord, since it may not receive enough amperage to operate correctly.
  • Page 30 PE6108AV / PE6208AV / PE8208AV User Manual PE6208AVG is the model used in the installation example picture above.
  • Page 31: Securing The Cables

    Chapter 2. Hardware Setup Securing the Cables For added safety, use ATEN Lok-U-Plug cable holders (not for PE6208AVX) to secure the cables from your attached devices in place on the eco PDU unit. Secure the cable holders using the specially designed holes around the individual power outlets, as shown below: Note: 1.
  • Page 32: Securing The Sensors

    PE6108AV / PE6208AV / PE8208AV User Manual Securing the Sensors Connect the sensors to the eco PDU’s rear panel sensor ports and secure them using sensor mounts, tie wraps, and adhesive cable tie holders. If you use a tie wrap to secure the sensor, tighten the tie wrap over the recessed channel on the sensor, as shown in the following diagram: Note: 1.
  • Page 33: Chapter 3. Basic Operation And

    Graphical Interface that allows you to configure a PDU device and monitor power status of the equipment connected to it. eco Sensors Energy Management Software can be downloaded from the ATEN website, along with a separate eco Sensors User Manual.
  • Page 34: First Time Setup

    PE6108AV / PE6208AV / PE8208AV User Manual First Time Setup Once the eco PDU installation has been cabled up, the next task the Administrator needs to perform involve configuring the network parameters, changing the default Super Administrator login settings, and adding users.
  • Page 35: Network Configuration

    Chapter 3. Basic Operation and First Time Setup Network Configuration To configure the network settings, do the following: 1. Click the Setup tab. 2. The interface displays the Device Configuration page. A screen similar to the one below appears: 3. Fill in the fields according to the information provided under Device Configuration, page 47.
  • Page 36: Changing The Administrator Login

    PE6108AV / PE6208AV / PE8208AV User Manual Changing the Administrator Login To change the default Administrator username and password, do the following: 1. Click the User tab. The Accounts page has a detailed list of users – with more information about them –...
  • Page 37: Chapter 4. Browser Operation

    Chapter 4 Browser Operation Logging In The eco PDU can be accessed via a supported Internet browser from any platform. Note: Browsers must support SSL 128 bit encryption. To access the eco PDU do the following: 1. Open your browser and specify the IP address of the eco PDU you want to access in the browser's URL location bar.
  • Page 38: The Eco Pdu Main Page

    PE6108AV / PE6208AV / PE8208AV User Manual The eco PDU Main Page After you have successfully logged in, the eco PDU Main Page comes up with the Energy Connections page displayed: Note: The screen depicts an Administrator’s page. Depending on a user’s type and permissions, not all of these elements appear.
  • Page 39 Chapter 4. Browser Operation Item Description Help Connects to on-line help at the ATEN website for the device’s configuration and operation. Logout Click this button to log out of your eco PDU session. Interactive Display Panel This is your main work area. The screens that appear reflect your menu choices and Sidebar node selection.
  • Page 40: Energy

    PE6108AV / PE6208AV / PE8208AV User Manual Energy Connections When you log in to the eco PDU, the interface opens with its default selection of the Energy tab; and the Connections menu. The contents of the PDU Status and Outlet Status sections are displayed in the main panel.
  • Page 41 Chapter 4. Browser Operation PDU Status All eco PDU models support PDU device level monitoring. The PDU Status section allows you to set up a power management configuration for the PDU device as a whole: PDU Threshold Settings These fields are used to set the maximum, minimum, and fluctuation threshold settings for Aggregate Current, Voltage, Power, and Aggregate Power Dissipation.
  • Page 42 PE6108AV / PE6208AV / PE8208AV User Manual Outlet Status (PE6208AV) The PE6208AV supports on, off and reboot control from the outlet status column for each outlet. On / Off / Reboot You can manually turn the outlet On and Off from this page by clicking the radio buttons.
  • Page 43 Chapter 4. Browser Operation Outlet Status (PE8208AV) The PE8208AV supports outlet level monitoring; and on, off and reboot control. The main panel Outlet Status section allows you to set up a power management configuration for each outlet at an individual level. Outlet Threshold Settings These fields are used to set the maximum, minimum, and fluctuation threshold settings for Current, Voltage, Power, and Power Dissipation.
  • Page 44: Configuration (Pe6208Av)

    PE6108AV / PE6208AV / PE8208AV User Manual Configuration (PE6208AV) The Configuration page is used to configure the settings of the PE6208AV at the individual power outlet level. POP Settings This section allows you to enable Proactive Overload Protection (POP). Proactive Overload Protection is triggered when the PDU’s Aggregate Current Max Threshold setting is exceeded (see page 31).
  • Page 45 Chapter 4. Browser Operation Bank POP Priority List Use the eight drop-down menus to set the priority for when Proactive Overload Protection powers off the outlets. The outlet set as Priority1 will be powered off first, Priority2 will be powered off second, and so on. Outlets set to N/A will not be powered off when Proactive Overload Protection is triggered.
  • Page 46: Configuration (Pe8208Av)

    PE6108AV / PE6208AV / PE8208AV User Manual Configuration (PE8208AV) The Configuration page is used to configure the settings of the PE8208AV at the individual power outlet level: POP Settings This section allows you to enable Proactive Overload Protection (POP). Proactive Overload Protection is triggered when a PDU’s or Outlet’s Current Max Threshold setting is exceeded.
  • Page 47 Chapter 4. Browser Operation Power On Time Schedule Settings Check the Enable Power On Time Schedule box to use the Power ON Delay setting to set the amount of time the eco PDU waits before powering on an outlet. See Power ON Delay in the table on the next page. Buzzer Setting Checking the Enable Buzzer Alarm box sounds an alarm and sends SNMP trap or e-mail alerts when a threshold setting exceeds the minimum...
  • Page 48 PE6108AV / PE6208AV / PE8208AV User Manual POP Setting Scenarios Setting Description Triggers Proactive Overload Protection to power off an outlet when it's Current Max Threshold setting is exceeded. Only the outlet that exceeds the threshold setting is powered off.
  • Page 49 Chapter 4. Browser Operation Outlet Configuration The Outlet Configuration section lets you set the power management settings for each outlet on the PDU. Heading Meaning Outlet Shows the port number of the listed outlet. Outlet Name Each outlet can be given a distinctive name. The maximum number of characters is 15.
  • Page 50 PE6108AV / PE6208AV / PE8208AV User Manual Heading Meaning Delay Time (sec) Sets the amount of time the eco PDU waits after the Power Button Power ON is clicked (see Outlet Status (PE6208AV), page 32), before it turns on the power to the outlet. You must check the Enable Power On Time Schedule Setting box for this setting to take effect.
  • Page 51 Chapter 4. Browser Operation Heading Meaning MAC Address In order to use either of the Safe Shutdown and Restart methods the MAC address of the computer connected to the outlet must be filled in here. Auto Ping Method Auto Ping Method pings a device at specified intervals and if there is no response (Request timed out) the PDU automatically powers cycles the outlet (off and then on).
  • Page 52: User

    PE6108AV / PE6208AV / PE8208AV User Manual User When you select the User tab the screen comes up with Administrator Information and User Information displayed in the main panel. The eco PDU supports one Administrator account and up to eight User accounts.
  • Page 53: User Information

    Chapter 4. Browser Operation SNMPv1/v2c Community Enter values Read community and Write community for SNMPv1/V2c authentication, if required. Telnet Use the Name and Password fields to change the account used to login via Telnet sessions. Click Save to save your settings. User Information To add a user, do the following: 1.
  • Page 54 PE6108AV / PE6208AV / PE8208AV User Manual Field Description Outlet This field allows you to set the outlet-by-outlet permissions of the user. Click on the user/port icon to cycle through the three permissions options, as follows: User has complete access to this outlet.
  • Page 55: Log

    Chapter 4. Browser Operation The Log tab keeps a record of transactions that take place on its installation, and stores up to 128 events at one time. The System Log page provides a powerful array of filters and functions that allow you to view and export the log file data, as well as be informed by email of specified events as they occur.
  • Page 56: Notification Settings

    PE6108AV / PE6208AV / PE8208AV User Manual Notification Settings The Notification Settings page is used to specify which of the eco PDU’s components will receive notification of a log event. When you click the Notification Settings menu item, a page similar to the one below appears: The event categories are listed in the left column.
  • Page 57: Setup

    Chapter 4. Browser Operation Setup The Setup tab provides Device Configuration and Security settings. The Device Configuration page allows administrators to configure eco PDU system settings. The Security page controls access to the PDU. Device Configuration This page presents information about the selected device, as described in the following sections: General Item...
  • Page 58 PE6108AV / PE6208AV / PE8208AV User Manual Service Ports As a security measure, if a firewall is being used, the Administrator can specify the port numbers that the firewall will allow. If a port other than the default is used, users must specify the port number as part of the IP address when they log in.
  • Page 59 Chapter 4. Browser Operation IPv4 Configuration The PDU’s IPv4 IP and DNS addresses (the traditional method of specifying IP addresses) can either be assigned dynamically (DHCP), or a fixed IP address can be specified. For dynamic IP address assignment, select the Obtain IP address automatically radio button.
  • Page 60 PE6108AV / PE6208AV / PE8208AV User Manual Event Notification The Event Notification section is divided into three sections: SMTP Server; SNMP Trap Receivers; and Syslog Server. Each section is described below. SMTP Server To have the eco PDU email reports from the SMTP server to you, do the following: 1.
  • Page 61 Chapter 4. Browser Operation SNMP Trap Receivers Up to four SNMP management stations can be specified. If you want to use SNMP trap notifications, do the following: 1. Check Enable SNMP Trap. 2. Select which version of SNMP you want to use. 3.
  • Page 62 PE6108AV / PE6208AV / PE8208AV User Manual Syslog Server To record all the events that take place on eco PDU devices and write them to the eco PDU Syslog server, do the following: 1. Check Enable Syslog Server. 2. Key in the IP address and the port number of the Syslog server. The valid...
  • Page 63: Date/Time

    Chapter 4. Browser Operation Date/Time The Date/Time dialog page sets the eco PDU time parameters: Time Zone To establish the time zone that the eco PDU is located in, drop down the Time Zone list and choose the city that most closely corresponds to where it is at.
  • Page 64 PE6108AV / PE6208AV / PE8208AV User Manual Manual Input Use this section to specify the eco PDU’s date and time manually. Click the calendar icon and click the calendar entry for the date. Key the time into the Time field, using the HH:MM:SS (hours, minutes, seconds) format.
  • Page 65: Security

    Chapter 4. Browser Operation Security The Security page controls access to the eco PDU device. Login Failures Allowed sets the number of consecutive failed login attempts that are permitted from a remote user. Timeout sets the amount of time a remote user must wait before attempting to login again after exceeding the number of allowed failures.
  • Page 66: Account Policy

    PE6108AV / PE6208AV / PE8208AV User Manual Account Policy The Account Policy section governs policies in regard to usernames and passwords. Check a policy and enter the required information in the appropriate fields. Item Description Minimum Username Length Sets the minimum number of characters required for a username.
  • Page 67: Login String / Ip Filter / Mac Filter

    Chapter 4. Browser Operation Login String / IP Filter / Mac Filter Login String The Login String entry field is used to specify a login string (in addition to the IP address) that users must include when accessing the eco PDU device with a browser.
  • Page 68 PE6108AV / PE6208AV / PE8208AV User Manual IP Filter / MAC Filter If any filters have been configured, they appear in the IP Filter and/or MAC Filter list boxes. IP and MAC Filters control access to the eco PDU based on the IP and/or MAC addresses of the client computers attempting to connect.
  • Page 69 Chapter 4. Browser Operation To add a MAC filter, do the following: 1. Click Add. A dialog box similar to the one below appears: 2. Specify the MAC address in the dialog box (for example, 001074670000), then click OK. Repeat these steps for any additional MAC addresses you want to filter. IP Filter / MAC Filter Conflict If there is a conflict between an IP filter and a MAC filter –...
  • Page 70: Authentication & Authorization

    PE6108AV / PE6208AV / PE8208AV User Manual Authentication & Authorization The Authentication & Authorization page is used to set up login authentication and authorization management from external sources. RADIUS Settings To allow authentication and authorization for the eco PDU device through a RADIUS server, do the following: 1.
  • Page 71: Private Certificate

    For enhanced security, the Private Certificate section allows you to use your own private encryption key and signed certificate, rather than the default ATEN certificate. There are two methods for establishing your private certificate: generating a self-signed certificate;...
  • Page 72 PE6108AV / PE6208AV / PE8208AV User Manual Importing the Private Certificate To import the private certificate, do the following: 1. Click Browse to the right of Private Key; browse to where your private encryption key file is located; and select it.
  • Page 73: Pdu

    Chapter 4. Browser Operation The PDU tab is used to upgrade the eco PDU’s firmware, and to backup and restore the device’s configuration settings. Firmware File When you click the Maintenance tab, the display opens with the Firmware Upgrade menu page, which looks similar to the one below: A description of the items shown in this panel are given in the table, below: Item Description...
  • Page 74 PE6108AV / PE6208AV / PE8208AV User Manual Upgrading the Firmware To upgrade the firmware refer to the screenshot on the preceding page, and do the following: 1. Go to our website and download the new firmware file to a convenient location on your computer.
  • Page 75: Backup/Restore

    Chapter 4. Browser Operation Backup/Restore Selecting Backup/Restore on the menu bar gives you the ability to back up the switch’s configuration and user profile information: Backup To backup the device’s settings do the following: 1. In the Password field, key in a password for the file. Note: Entering a password is optional.
  • Page 76 PE6108AV / PE6208AV / PE8208AV User Manual This Page Intentionally Left Blank...
  • Page 77: Rs-232 / Telnet Commands

    RS-232 / Telnet Commands Remote Terminal Operations With ATEN PE6108AV / PE6208AV / PE8208AV you can log in remotely from a computer using Telnet or via the built-in bi-directional RS-232 serial interface that allows system control through a high-end controller or PC.
  • Page 78 PE6108AV / PE6208AV / PE8208AV User Manual Note: If the Enable Telnet Server option is not available, please download the latest firmware from our website. Logging In To log in to the eco PDU via Telnet, do the following: 1. On your computer, open the start menu and select Run. Type: cmd Click OK.
  • Page 79: Rs-232 Serial Control

    Chapter 5. RS-232 / Telnet Commands RS-232 Serial Control This section provides the serial control settings and PIN assignments used to configure the RS-232 Serial Port. RS232 Pin Assignment Description Description Not connected Not connected Not connected Not connected Not connected Not connected Configuring the Serial Port The controller’s serial port should be configured as follows:...
  • Page 80: Commands

    PE6108AV / PE6208AV / PE8208AV User Manual Commands Use the Telnet and RS-232 text commands to view and configure the eco PDU as described in each section. The text-based command line provides some of the same functions found under the Energy tab of the eco PDU’s web-based GUI.
  • Page 81: Read Outlet Status

    Chapter 5. RS-232 / Telnet Commands Read Outlet Status The Read Outlet Status command allows you to view the power status of an outlet on the eco PDU. The formula for Read Outlet Status commands is as follows: Command + Outlet + Number + Return String + [Enter] 1.
  • Page 82 PE6108AV / PE6208AV / PE8208AV User Manual Note: 1. Each command string can be separated with a space. 2. The Return String command string can be skipped and format will be used by default.
  • Page 83: Switch Outlet Status

    Chapter 5. RS-232 / Telnet Commands Switch Outlet Status The Switch Outlet Status command allows you to change the power status of an outlet on the eco PDU. The formula for Switch Outlet Status commands is as follows: Command + Outlet + Number + Control + Option + [Enter] 1.
  • Page 84 PE6108AV / PE6208AV / PE8208AV User Manual The following table lists the available Switch Outlet Status commands: Command Outlet Control Option Enter Description imme [Enter] Switch outlet XX on with option delay XX: Outlet number imme [Enter] Switch outlet XX off with...
  • Page 85: Read Power Value

    Chapter 5. RS-232 / Telnet Commands Read Power Value The Read Power Value command allows you to view the power measurement values of the eco PDU, Bank or Outlet. The formula for Read Power Value commands is as follows: Command + Target + Number + Measurement + Return String + [Enter] 1.
  • Page 86 PE6108AV / PE6208AV / PE8208AV User Manual Measurement Description Read power dissipation measurement Read power factor measurement freq Read voltage frequency measurement Return String Description simple Return simple string measurement format Return format string measurement The following table lists the available Read Power Value commands:...
  • Page 87: Read Environmental Value

    Chapter 5. RS-232 / Telnet Commands Read Environmental Value The Read Environmental Value command allows you to view measurements from the eco PDU’s environmental sensors. The formula for Read Environmental Value commands is as follows: Command + Sensor + Number + Return String + [Enter] 1.
  • Page 88: Close Telnet Session

    PE6108AV / PE6208AV / PE8208AV User Manual Note: 1. Each command string can be separated with a space. 2. The Return String command string can be skipped and format will be used by default. Close Telnet Session The Close Telnet Session command allows you to disconnect the telnet session from the eco PDU.
  • Page 89: Safety Instructions

    Appendix Safety Instructions General This product is for indoor use only. Read all of these instructions. Save them for future reference. Follow all warnings and instructions marked on the device. Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.
  • Page 90 PE6108AV / PE6208AV / PE8208AV User Manual purpose of the grounding-type plug. Always follow your local/national wiring codes. The equipment should be installed near the wall socket outlet and the disconnect device (appliance coupler) should be readily accessible. Do not allow anything to rest on the power cord or cables. Route the power cord and cables so that they cannot be stepped on or tripped over.
  • Page 91 Appendix Do not connect the RJ-11 connector marked “Sensor” to a public telecommunication network.
  • Page 92: Consignes De Sécurité

    PE6108AV / PE6208AV / PE8208AV User Manual Consignes de sécurité Général Ce produit est destiné exclusivement à une utilisation à l’intérieur. Veuillez lire la totalité de ces instructions. Conservez-les afin de pouvoir vous y référer ultérieurement. Respectez l’ensemble des avertissements et instructions inscrits sur l’appareil.
  • Page 93 Appendix L’unité est équipée d’une fiche de terre à trois fils. Il s’agit d’une fonction de sécurité. Si vous ne parvenez pas à insérer la fiche dans la prise murale, contactez votre électricité afin qu’il remplace cette dernière qui doit être obsolète.
  • Page 94 PE6108AV / PE6208AV / PE8208AV User Manual L’unité a été exposée à la pluie ou à l’eau. L’unité est tombée ou le boîtier a été endommagé. Les performances de l’unité sont visiblement altérées, ce qui indique la nécessité d’une réparation.
  • Page 95: Rack Mounting

    To secure the cables in the eco PDU’s power outlets, use only the ATEN Lok-U-Plug cable holders that have been specifically designed to work with the eco PDU. Using any other kind of cable securing device could be highly dangerous. Please contact your ATEN dealer for information about ATEN Lok-U-Plugs.
  • Page 96: Montage Sur Bâti

    Fixation des câbles d’alimentation Pour fixer les câbles aux sorties d’alimentation de l’unité d’alimentation éco, utilisez uniquement les supports de câble Lok- U-Plug d’ATEN qui ont été conçus spécialement pour être utilisés...
  • Page 97 Appendix avec l’unité d’alimentation éco. L’utilisation de tout autre type système de fixation de câble pourrait s’avérer très dangereuse. Veuillez contacter votre revendeur ATEN pour plus d’informations sur le support de câble ATEN Lok- U-Plug.
  • Page 98: Technical Support

    PE6108AV / PE6208AV / PE8208AV User Manual Technical Support International For online technical support – including troubleshooting, documentation, and software updates: http://eservice.aten.com For telephone support, see Telephone Support, page iii North America Email Support support@aten-usa.com Online Troubleshooting http://eservice.aten.com Technical Documentation...
  • Page 99: Ip Address Determination

    Appendix IP Address Determination If you are an administrator logging in for the first time, you need to access the eco PDU in order to give it an IP address that users can connect to. There are two methods to choose from. In each case, your client computer must be on the same network segment as the eco PDU.
  • Page 100 PE6108AV / PE6208AV / PE8208AV User Manual (Continued from previous page.) 3. Select the device in the Device List. Note: 1. If the list is empty, or your device doesn't appear, click Enumerate to refresh the Device List. 2. If there is more than one device in the list, use the MAC address to pick the one you want.
  • Page 101: Specifications

    Appendix Specifications PE6108AVA Function PE6108AVA Electrical Nominal Input Voltage 100-120VAC Maximum Input Current 15A (Max), 12A (UL de-rated) Frequency 50-60Hz Input Connection For A/J Plug: NEMA 5-15P Input Power 1800VA (Max),1440VA (UL de-rated) Outlet Type Total: 8 x NEMA 5-15R Nominal Output Voltage 100-120VAC Maximum Output Current...
  • Page 102 PE6108AV / PE6208AV / PE8208AV User Manual Function PE6108AVA Compliance EMC Verification FCC, J55032 Safety Verification...
  • Page 103: Pe6208Ava / Pe6208Avb / Pe6208Avg / Pe6208Avx

    Appendix PE6208AVA / PE6208AVB / PE6208AVG / PE6208AVX Function PE6208AVA PE6208AVB PE6208AVG PE6208AVX Electrical Nominal Input 100-120VAC 100-240VAC 100-240VAC 100-240VAC Voltage Maximum Input 20A (Max), 16A 20A (Max), 16A 16A (Max) Current (UL de-rated) (UL de-rated) Frequency 50-60Hz Input Connection A/J:NEMA L5- NEMA 6-20P IEC 60320 C20...
  • Page 104 PE6108AV / PE6208AV / PE8208AV User Manual Function PE6208AVA PE6208AVB PE6208AVG PE6208AVX Power Cord N.A. Length Environmental Temperature 0-50°C / -20-60°C 0-50°C / -20-60°C 0-40°C / -20-60°C 0-50°C / -20-60°C (Operating / Storage) Humidity 0-80% RH, Non-Condensing (Operating & Storage)
  • Page 105: Pe6208Avj Japan

    Appendix PE6208AVJ Japan 型番 PE6208AVJ 電気仕様 定格入力電圧 AC100–240V 最大入力電流 20A (最大)、 16A (UL デ ィ レーテ ィ ン グ) 入力周波数 50–60 Hz 入力側 イ ン タ ー IEC C20×1 ( リ ア側) フ ェ ース 負荷容量 4160 VA (最大)、 3328 VA (UL デ ィ レーテ ィ ン グ) ア...
  • Page 106 PE6108AV / PE6208AV / PE8208AV User Manual 型番 PE6208AVJ コ ネ ク タ ー RJ-45×1 ( リ ア側) セ ンサーポー ト RJ-11×2 ( リ ア側、 49 cm カ テ ゴ リ 5 ケーブル) RS-232 DB-9×1 ( リ ア側) ボ タ ン...
  • Page 107: Pe8208Avb / Pe8208Avg

    Appendix PE8208AVB / PE8208AVG Function PE8208AVB PE8208AVG Power Outlets Direct Connectors Power Inlet 1 x IEC 320 C20 Power Outlets 8 x IEC 320 C13 Sensor 2 x RJ-11 1 x RJ-45 (F) RS-232 1 x DB-9 (M) LEDs Current / IP 2-digit 7-segment (Yellow) Outlet Power 8 (Orange)
  • Page 108: Pe8208Avj Japan

    PE6108AV / PE6208AV / PE8208AV User Manual PE8208AVJ Japan 型番 PE8208AVJ 電気仕様 定格入力電圧 AC100–240V 最大入力電流 20A (最大)、 16A (UL デ ィ レーテ ィ ン グ) 入力周波数 50–60 Hz 入力側 イ ン タ ー IEC C20×1 ( リ ア側) フ ェース...
  • Page 109 Appendix 型番 PE8208AVJ コ ネ ク タ ー RJ-45×1 ( リ ア側) セ ンサーポー ト RJ-11×2 ( リ ア側、 49 cm カ テ ゴ リ 5 ケーブル) RS-232 DB-9×1 ( リ ア側) ボ タ ン ピ ン ホール型ス イ ッ チ ×1 (フ ロ ン ト 側) リ...
  • Page 110: Administrator Login Failure

    PE6108AV / PE6208AV / PE8208AV User Manual Administrator Login Failure If you are unable to perform an Administrator login (because the Username and Password information has become corrupted, or you have forgotten it, for example), you can clear the login information with the following procedure: 1.
  • Page 111: Limited Warranty

    ATEN will provide a repair service, without charge, during the Warranty Period. If a product is detective, ATEN will, at its discretion, have the option to (1) repair said product with new or repaired components, or (2) replace the entire product with an identical product or with a similar product which fulfills the same function as the defective product.
  • Page 112 PE6108AV / PE6208AV / PE8208AV User Manual...

This manual is also suitable for:

Pe6208avPe8208av

Table of Contents