ATEN RCMDVI00BT User Manual page 173

Secure device server
Table of Contents

Advertisement

Heading
Network
HTTP Port
Ports
Device Port
HTTPS Port
Fast Switching
Account
Enforce Password
Policy
History
Enhance Password
Rule
Item
Sets the HTTP service port used to access the
RCM/KE Manager. This is the port number to use
for a browser login. The default is 8080.
Sets the device service port used to access the
RCM/KE Manager. Configure this port number on
the transmitter and receiver to match the RCM/KE
Manager software (see Manager Address,
page 61 and 65). The default is 9110.
Sets the HTTPS service port used to access the
RCM/KE Manager, for secure browser login. The
default is 8443.
Example: To access the RCM/KE Manager with
an IP address of 192.168.0.100 using a secure
browser login, enter: https://192.168.0.100:8443
Select the default resolution to use so that you
can switch faster when changing receiver-to-
transmitter connections. If the monitor you are
using does not support fast switching, the video
may not display correctly when this setting is
enabled.
Note: Make sure to disable Boundless Switching
when Fast Switching is enabled.
This setting determines the number of unique new
passwords that must be used before an old
password can be reused. Uncheck the box and
enter a number to enforce the password history
policy.
Select Enable to enforce rules for creating
passwords, as follows:
The password length must be at least 8 charac-
ters.
The password must contain both upper and
lowercase characters.
The password must contain a number (0
through 9).
If a user types in the wrong password 5 times
consecutively, their account will be locked out
for 10 minutes.
Chapter 8. System Settings