To log into the RCM/KE series device by means of a RS-232 session, do the
following:
1. The controller's serial port should be configured the same as the receiver's
default configuration, as shown below:
The receiver's Function Switch should be set to RS-232 Config (see page 11).
Before executing RS-232 commands across a network you must install the
KVM over IP Matrix Manager on a computer and ensure that it is online.
Please make sure the RS-232 Serial Port is not connected before executing
commands.
2. Please press [T/t] to start "TextMenu" The login screen appears. At the
login prompt, provide the Password.
Note: The default password for Telnet sessions is password.
Chapter 6. Browser / Telnet Operation
Baud Rate
9600
Data Bits
Parity
None
Stop Bits
Flow Control
None
8
1