P08 Group Enhanced Functions - INVT SPC Series Operation Manual

Solar pump inverter
Table of Contents

Advertisement

SPC Series Solar Pump Inverter

P08 group Enhanced functions

Function
code
Auto fault reset
P08.28
Auto fault reset
P08.29
Name
Setting range: 0–10
The following faults can be automatically
reset:
OC1: Overcurrent during acceleration
OC2: Overcurrent during deceleration
OC3: Overcurrent during constant speed
running
OV1: Overvoltage during acceleration
OV2: Overvoltage during deceleration
OV3: Overvoltage during constant speed
running
UV: Bus undervoltage fault
OL1: Motor overload
OL2: Inverter overload
count
SPO: Phase loss on output side
EF: External fault
CE: RS485 communication fault
ItE: Current detection fault
tE: Motor autotuning fault
EEP: EEPROM operation error
END: Running time reached
OL3: Electronic overload
ETH1: To-ground short-circuit fault 1
ETH2: To-ground short-circuit fault 2
dEu: Speed deviation fault
STo: Mal-adjustment fault
LL: Underload fault
0.1–3600.0s
interval
Description
-34-
Function parameter list
Default Modify
5
10.0s