Output Setting - R&S NGM202 User Manual

Hide thumbs Also See for NGM202:
Table of Contents

Advertisement

®
R&S
NGL200/NGM200
<current>
<output>
Example:

7.5.7 Output Setting

The OUTPut subsystem contains the commands for activating the output channels.
User Manual 1178.8736.02 ─ 06
DEFault
Default voltage.
*RST:
1.000
Default unit: V
numeric | MIN | MAX | DEFault
numeric
Numeric value for current in the range of 0.000 to 6.010.
MIN
Min current at 0.000 A.
MAX
Max value for current at 6.010 A.
DEFault
Numeric value for current.
*RST:
1.000
Default unit: A
OUT1 | OUTP1 | OUTPut1 | OUT2 | OUTP2 | OUTPut2
OUT1 | OUTP1 | OUTPut1
Selects output for channel 1.
OUT2 | OUTP2 | OUTPut2
Selects output for channel 2.
INST OUT1
APPL 6,2
Sets 6 V and 2 A to output of channel 1.
APPL? -> 6.000, 2.000
Queries the voltage and current of the selected channel.
Remote Control Commands
Configuration Commands
110

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ngm200 seriesNgl200 seriesNgl-com2aNgl201Ngl202Ngm201

Table of Contents