Measure[:Scalar]:Power; Measure[:Scalar]:Statistic:count; Measure[:Scalar]:Statistic:reset; Measure[:Scalar]:Current[:Dc] - R&S NGM202 User Manual

Hide thumbs Also See for NGM202:
Table of Contents

Advertisement

®
R&S
NGL200/NGM200
Example:

MEASure[:SCALar]:POWer?

Queries the currently supplied power of the selected channel.
Example:
Usage:

MEASure[:SCALar]:STATistic:COUNt?

Queries the number of measurements.
Usage:

MEASure[:SCALar]:STATistic:RESet

Resets the minimum, maximum and average statistics values for voltage, current, and
power.
Additionally this command resets the measured energy.

MEASure[:SCALar]:CURRent[:DC]?

Queries the currently measured current of the selected channel.
Example:
Usage:

MEASure[:SCALar][:CURRent][:DC]:AVG?

Queries the average measured output current.
Usage:

MEASure[:SCALar][:CURRent][:DC]:MAX?

Queries the maximum measured output current.
Usage:

MEASure[:SCALar][:CURRent][:DC]:MIN?

Queries the minimum measured output current.
User Manual 1178.8736.02 ─ 06
INST OUT1
MEAS:ENER:STAT ON
MEAS:ENER:STAT?
MEAS:ENER:STAT? -> 1
Energy counter of Ch1 is enabled.
MEAS:POW? -> 3.00E+00
Query only
Query only
MEAS:CURR? -> 1.000E +00
Query only
Query only
Query only
Remote Control Commands
Measurement Commands
128