Switching On The Instrument - R&S NGM202 User Manual

Hide thumbs Also See for NGM202:
Table of Contents

Advertisement

®
R&S
NGL200/NGM200
Option IEEE-488 (GPIB) interface (14)
An IEEE-488 (GPIB) interface can be ordered (NGL-B105 or NGM-B105). This inter-
face is not user installable.
Digital I/O connector (15)
The Digital I/O option (R&S NGL-K103 or R&S NGM-K103) must be installed for this
function to be available in the instrument.
The specified voltages are 0 V to 24 V for all output pins and 0 V to 15 V for all input
pins.
Figure 4-4: Digital I/O connector (female socket front view)
Table 4-2: Digital I/O pin layout
Pin
1
2
3
4
5 - 8
* The
Table 4-3: Inhibit signals
Signal name
Inhibit Ch1
Inhibit Ch2

4.2.2 Switching On the Instrument

Before switching on the instrument, check that all the instructions in the "Basic Safety
Instruction" brochure and safety measures in previous sections are observed. Also,
check if the value on the voltage selector corresponds to the mains voltage (100 V, 115
V or 230 V).
User Manual 1178.8736.02 ─ 06
Signal
Direction
*Inhibit Ch1
IN
Trigger Ch1
IN
In
IN
Out1
OUT
Gnd
-
inhibit signals
can be used to turn off the outputs by a digital hardware signal.
Pin
Pin 1 of
nector
Pin 9 of
nector
Pin
Signal
9
*Inhibit Ch2
10
Trigger Ch2
11
Output Fault
12
Out2
13 - 15
Gnd
Descriptions
Digital I/O con-
If the inhibit signal goes active, channel 1 output
is turned off.
The inhibit signal is low active (inverted logic).
Digital I/O con-
If the inhibit signal goes active, channel 2 output
is turned off
The inhibit signal is low active (inverted logic).
Getting Started
Instrument Tour
Direction
IN
IN
OUT
OUT
-