The 682 indicator provides a number of error messages. When an error occurs, the message displays on the indicator.

16.1.1 Displayed Error Messages

The 682 provides a number of front panel error messages to assist in problem diagnosis.
their meanings.
Error Message
-------
v v v v v v v
Battery low
Waiting for 30 seconds of standstill
Not allowed in motion
Tare in motion not allowed
Tare not allowed
Negative tare not allowed
Keyed tare not allowed
Tare exceeding capacity not allowed Displays when attempting to perform a tare larger than capacity, if it is not allowed
Multiple tares not allowed
Must be in first interval to tare
Keyed tare value must be in first
interval
Duplicate ID not allowed
Invalid ID
Truck ID not found
Truck program disabled
Truck program error
Invalid Index
Invalid Weight
Record read error
Record write error
Initial zero failed
Please wait
Alarm
108
Visit our website
Table 16-1. 682 Error Messages
Overflow error – Weight value too large to be displayed
Gross > overload limit – Gross value exceeds overload limit; Check configuration or signal input level; Overload can
be caused by input signal > 45 mV or common mode voltage > 950 mV
Gross < underload limit – Gross value exceeds underload limit
Displays every 30-seconds when battery is low
Displays when power up delay is active
Displays when attempting to perform a function while weight is in motion, if in motion is not allowed for that function
Displays when attempting to perform a tare while weight is in motion, if in-motion tares are not allowed
Displays when attempting to perform a tare, if a tare is not allowed
Displays when attempting to perform a negative tare, if a negative tare is not allowed
Displays when attempting to perform a keyed tare, if a keyed tare is not allowed
Displays when attempting to perform a tare if a tare is already in the system, if tare is not configured to
replace or remove
Interval is currently within the second or third interval; Perform tare while in the first interval only
Keyed tare value is within the second or third interval; Keyed tare value must be within the first interval only
Displays when attempting to enter a Truck ID that already exists, if ID Overwrite is set to Disable
Displays when attempting to enter an invalid Truck ID; Truck IDs can be up to 16 alphanumeric characters in length
Displays when attempting to enter a Truck ID at Weigh Out that has not been previously entered
Displays when attempting a Truck Mode function, when Truck Mode is set to Off
Generic error for the truck program
Displays when attempting to delete a truck ID record with an invalid index
Displays when weigh-in/-out procedure weight is invalid
Displays when an error occurs while reading from the microSD card or the CRC wasn't valid on the record
Displays when an error occurs while writing to the microSD card
Displays when an attempt to perform an initial zero fails, only possible at startup
Displays when calibrating
Displays when a configured setpoint's ALARM action occurs
www.RiceLake.com
Table 16-1
lists these messages and
Description

Advertisement

Table of Contents
loading

Table of Contents