11.1 Error Messages

The 680HE indicator provides a number of error messages. When an error occurs, the message is displays on the indicator.

11.1.1 Displayed Error Messages

The 680HE provides a number of front panel error messages to assist in problem diagnosis.
and their meanings.
Error Message
------
vvvvvv
battery low
tare in motion not allowed
negative tare not allowed
keyed tare not allowed
tare larger than capacity
not allowed
tare already in system
initial zero failed
please wait
alarm

11.2 ZZ EDP Command

The ZZ EDP command can be used to remotely query which annunciators are currently displayed on the indicator front panel.
The ZZ command returns a decimal number representing the LED annunciators currently lit
Example: If the annunciator status value returned on the ZZ command is 145, the gross, standstill and lb annunciators are lit. The
number 145 represents the sum of the values for the gross mode annunciator (16), the standstill annunciator (128) and
the lb annunciator (1).
62
Visit our website
Overflow error – Weight value too large to be displayed
Gross > overload limit – Gross value exceeds overload limit; Check configuration or signal input level; Overload can
be caused by input signal > 45 mV or common mode voltage > 950 mV
Gross < underload limit – Gross value exceeds underload limit
Scrolls across display every 30 seconds when battery is low
Scrolls across display when attempting to perform a tare while weight is in motion, if in motion tares are not allowed
Scrolls across display when attempting to perform a negative tare, if a negative tare is not allowed
Scrolls across display when attempting to perform a keyed tare, if a keyed tare is not allowed
Scrolls across display when attempting to perform a tare larger than capacity, if it is not allowed
Scrolls across display when attempting to perform a tare if a tare is already in the system, if tare is not configured to
replace or remove
Scrolls across display when an attempt to perform an initial zero fails, only possible at startup
Scrolls across display when calibrating
Displays when a configured setpoint's ALARM action occurs
Table 11-1. 680HE Error Messages
Decimal Value
1
lb/primary units
2
kg/secondary units
4
Tare entered
8
Keyed tare entered
16
Gross
32
Net
64
Center of zero
128
Standstill