Digital I/O Menu; Analog Output Menu - Rice Lake REVOLUTION 682 Synergy Plus Technical Manual

Digital weight indicator
Table of Contents

Advertisement

682 Synergy Plus
4.5.9

Digital I/O Menu

This section provides a flow chart and descriptions for the Digital I/O menu.
Parameter
Bit 1-4
Digital I/O Bit 1-4 – Specifies the mode and function of the digital I/O pins; Settings: Off (default), Print, Zero, Tare, Units,
Primary, Secondary, Clear, Display Accumulator, Display Tare, Clear Accumulator, Clear Tare, Net/Gross, Gross, Net,
Clear Consecutive Number, Keyboard Lock, Batch Run, Batch Start, Batch Pause, Batch Reset, Batch Stop, Output

4.5.10 Analog Output Menu

This section provides a flow chart and descriptions for the Analog Output menu. The Analog Output menu is only functional if
the analog output option card is installed. If the option card is not installed, the menu is visible, but not functional. If the analog
output option card is installed, configure all other indicator functions and calibrate the indicator before configuring the analog
output. Instructions to install and setup the analog output option card are provided with the option card kit (PN 195084).
Digital I/O
Tweak Span
Parameter
Source
Specifies the scale tracked by the analog output; Only appears if the Regulatory Mode parameter is set to Industrial;
Settings: Scale 1 (default), Remote
Mode
Specifies the weight data, gross or net, tracked by the analog output when the Source parameter is assigned to a scale;
Settings: Gross (default), Net
Specifies the type/range of the output; Settings: 0-10V (default), 0-20MA, 4-20MA
Output
Error Action
Specifies how the analog output responds to system error conditions; Settings:
Full Scale (default) – Set to full scale (10 V or 20 mA)
Hold – Holds current value
Zero Scale – Sets to zero value (0 V, 0 mA or 4 mA)
Minimum
Specifies the minimum weight value tracked by the analog output; Enter value: ±9999999.0, 0.0 (default)
Weight
Maximum
Specifies the maximum weight value tracked by the analog output; Enter value: ±9999999.0, 10000.0 (default)
Weight
Tweak Zero
Adjusts the offset of the analog output zero value; Enter value: 0–65535, 0 (default)
Tweak Span
Adjusts the offset of the analog output span value; Enter value: 0–65535, 59515 (default)
52
Visit our website
Figure 4-25. Digital I/O Menu
User
Setpoint
Slot 0
Table 4-22. Digital I/O Menu Parameters
Figure 4-26. Analog Output Menu
User
Setup
Analog Output
Source
Minimum Weight
Maximum Weight
Table 4-23. Analog Output Menu Parameters
www.RiceLake.com