Calibration Menu - Rice Lake REVOLUTION 682 Synergy Plus Technical Manual

Digital weight indicator
Table of Contents

Advertisement

4.5.3

Calibration Menu

This section provides a flow chart and descriptions for the Calibration menu.
User
Scale Format
Temp Zero
Point 4
Parameter
Executes the zero calibration process
Zero Calibration
Displays the raw count value at the zero weight; A zero calibration generates this raw count value; Manually changing this count value
Zero Counts
changes the zero weight and negates the zero calibration
Sets the test weight value for the span calibration
Test Weight
Executes the span calibration process
Span Calibration
Displays the raw count value at the span weight; A span calibration generates this raw count value; Manually changing this count value
Span Counts
changes the span weight and negates the span calibration
Linear Calibration Linear or multi-point calibration is performed by entering up to four additional calibration points
Points 1-4 have the following sub-parameters:
Linear Point # Weight – Sets the test weight value for the linear calibration point
Calibrate Linear Point # – Executes the linear calibration process for the point; generates the raw count value for the test weight
value for Point #
Linear Point # Counts – Displays the raw count value at the linear point weight; A linear calibration generates this raw count
value; Manually changing this count value changes the linear point weight and negates the linear calibration for the point
Removes an offset value from the zero and span calibrations
Rezero
Takes last push button zero in the system (from Weigh mode) and uses it as the new zero reference point, after which a new span
Last Zero
calibration must be performed; this calibration cannot be performed when calibrating a scale for the first time
Temporarily zeros the displayed weight of a non-empty scale, after a span calibration was performed;
Temp Zero
The difference between the temporary zero and the previously calibrated zero value is used as an offset
Figure 4-9. Calibration Menu
Setup
Tare
Calibration
Communications
Zero Calibration
Zero Counts
Linear Calibration
Rezero
Point 1
Point 2
Table 4-8. Calibration Menu Parameter
(Section 6.1 on page
(Section 6.1 on page
(Section 6.1.1 on page
© Rice Lake Weighing Systems ● All Rights Reserved
Test Weight
Span Calibration
Last Zero
Temp Zero
Point 3
Point 4
Description
56)
56); Enter value: 0.000001–9999999.999999, 10000.0 (default)
56)
(Section 6.2.3 on page
57)
Configuration
Span Counts
(Section 6.1.2 on page
57);
(Section 6.2.1 on page
(Section 6.2.2 on page
57)
57)
35