6.0

Appendix

6.1

Error Messages

The IQ 700IS indicator provides a number of error and status messages. When an error occurs, the message is
shown on the indicator LCD display. Table 6-1 lists these messages and their meanings.
Error Message
Err1
Loss of configuration
Err1a
Loss of option configuration
Err1b
Err1c
Err2
Loss of zero calibration
Err3
Loss of span calibration
Err5
Loss of auto tare
Err6
Loss of auto zero
Err9
Not in span calibration
Err 10H
Input > 3.3 mV/V at full scale
Err 10L
Input < 0.4 mV/V at full scale
Err 10P
PTZ (push to zero) > 2%
Err 10–
PTZ > weight used for span calibration
OL
Gross overload
UL
Gross underrange
CAL
Calibration successful
30
IQ 700IS Installation Manual
Description
Reconfigure
Recalibrate
Acquire tare
Acquire zero
Program span value before entering
Recalibrate span to set full scale in the range 0.4–3.3 mV/V
Perform zero calibration
Check load cell wiring
Table 6-1. IQ 700IS Error Messages