Appendix; 10.1 Error Messages; 10.1.1 Displayed Error Messages; 10.2 Zz Edp Command - Rice Lake 380 Synergy Technical Manual

Digital weight indicator
Table of Contents

Advertisement

380 Synergy Digital Weight Indicator
10.0

Appendix

10.1 Error Messages

The 380 indicator provides a number of error messages. When an error occurs, the message displays on the indicator.

10.1.1 Displayed Error Messages

The 380 provides a number of front panel error messages to assist in problem diagnosis.
their meanings.
Error Message
-------
vvvvvvv
tare in motion not allowed
negative tare not allowed
keyed tare not allowed
tare larger than capacity
not allowed
tare already in system
initial zero failed
please wait

10.2 ZZ EDP Command

The ZZEDP command can be used to remotely query whatever is being displayed on the LCD Display, along with a decimal
number representing the annunciators currently lit. The format on the returned value is WWWWWW UU NNN in weight display
modes, and VVVVVV NNN in non-weight display modes. NNN is a number between 0 and 4095, and is the sum of values
representing the different annunciators
Example: If the annunciator status value returned for the ZZ command is 0145, the gross, standstill and lb annunciators are on.
The number 0145 represents the sum of the values for the gross mode annunciator (16), the standstill annunciator
(128) and the lb annunciator (1).
Standstill bit is set when the In-Motion annunciator is NOT lit.
Note
44
Visit our website
Overflow error – Weight value too large to be displayed
Gross > overload limit – Gross value exceeds overload limit; Check configuration or signal input level; Overload can
be caused by input signal > 45 mV or common mode voltage > 950 mV
Gross < underload limit – Gross value exceeds underload limit
Scrolls across display when attempting to perform a tare while weight is in motion, if in motion tares are not allowed
Scrolls across display when attempting to perform a negative tare, if a negative tare is not allowed
Scrolls across display when attempting to perform a keyed tare, if a keyed tare is not allowed
Scrolls across display when attempting to perform a tare larger than capacity, if it is not allowed
Scrolls across display when attempting to perform a tare if a tare is already in the system, if tare is not configured to
replace or remove
Scrolls across display when an attempt to perform an initial zero fails, only possible at startup
Scrolls across display when calibrating
Table 10-1. Error Messages
(Table
10-2).
Decimal Value
1
lb units
2
kg units
4
Tare entered
8
Keyed tare entered
16
Gross
32
Net
64
Center of zero
128
Standstill
256
oz units
512
tn units
1024
t units
2048
g units
Table 10-2. Status Codes Returned on the ZZ Command
www.RiceLake.com
Table 10-1
Description
Annunciator
lists these messages and

Advertisement

Table of Contents
loading

This manual is also suitable for:

380 synergy series380-2dSynergy 380

Table of Contents