682 Synergy Plus
4.5.5.1 Industrial Settings Menu
This section provides a flow chart and descriptions for the Industrial Settings menu. The Industrial Settings menu only displays
if the Regulatory Mode parameter is set to Industrial.
User
Setup
Communications
Program
Industrial
Regulatory Mode
Settings
Underload Weight
Audit Agency
Allow Clear Tare
Key
Tare in Motion
Parameter
Audit Agency
Weight Source for Print
Remove Tare on Zero
Allow Keyed Tare
Multiple Tare Action
Allow Negative Tare
Allow Clear Tare Key
Negative Total
Allow Print in Motion
Add PT to Keyed Tare Print
Zero Base for Overload
Auto-Zero Tracking on Net Zero
Manual Clear Tare
Tare in Motion
Zero in Motion
Underload Weight
44
Visit our website
Figure 4-17. Industrial Settings Menu
Tare
Print Format
Truck Program
Weight Source for
Remove Tare on
Print
Allow Print in
Negative Total
Motion
Zero in Motion
Underload Weight
Table 4-16. Industrial Settings Menu Parameters
Audit trail display agency format; Settings: NTEP (default), Measurement Canada, None, OIML
Display or scale weight source for print; Settings: Display (default), Captured Scale Zero
Remove tare on zero; Settings: No (default), Yes
Always allow keyed tare; Settings: Yes (default), No
Replaces existing tare when the tare key is pressed; Settings: Replace (default), Remove, Nothing
Allow negative or zero tare; Settings: No (default), Yes
Allow clear key to clear tare or accumulator when displayed; Settings: Yes (default), No
Allow total scale to display negative value; Settings: No (default), Yes
Allow print while in motion; Settings: No (default), Yes
Add preset tare (PT) to keyed tare print; Settings: Yes (default), No
Zero base for overload calculation; Settings: Calibrated Zero (default), Captured Scale Zero
Perform auto zero tracking on net zero; Settings: No (default), Yes
Allow manual clearing of the tare value; Settings: Yes (default), No
Allow tare in motion; Settings: No (default), Yes
Allow scale to be zeroed while in motion; Settings: No (default), Yes
Underload weight value in display divisions; Enter value: 1–9999999, 20 (default)
www.RiceLake.com
Allow Keyed Tare
Zero
Add PT to Keyed
Zero Base for
Tare Print
Overload
Description
Multiple Tare
Allow Negative
Action
Tare
Auto-Zero
Tracking on Net
Manual Clear Tare
Zero