Send the pump to an Edwards Service Centre for a bearing replacement.
Purchase a bearing service kit and replace the bearing on-site (refer to
site maintenance

8.2 Rotor life

The fatigue life of nEXT Turbomolecular pump rotors is typically 40,000 to 50,000 cycles.
As a precautionary measure, Edwards recommends that pumps are returned for a major
service (rotor replacement) after 20,000 cycles of acceleration to full speed and back to
a stop, or after ten years of use, whichever occurs first.

8.3 Cleaning the pump

WARNING:
Clean the external surfaces of the pump in a well ventilated location. When using
cleaning solutions and solvents to clean the pump, observe all precautions specified
by the manufacturer. Avoid inhalation of any particulates which may be present in
the pump.
NOTICE:
Do not attempt to clean any parts of the pump other than external surfaces. Organic
solvents may damage internal pump components. Do not use abrasive materials to
clean any part of the pump.
If the inside of the pump is contaminated, it may not be possible to achieve the specified
ultimate vacuum performance, or pump-down times may increase.
In these circumstances the pump must be returned to an Edwards Service Centre where
the pump will be dismantled and cleaned. Refer to
for service
Any organic solvent can be used to clean the external surfaces of the pump. Edwards
recommend the use of non-CFC solvents such as isopropanol or ethanol. Only a minimal
amount of a cleaning solution is required which is suitable for the contaminants on the
pump surfaces.
For environmental reasons, keep wastage of cleaning solutions and solvents to a
minimum.

8.4 Decoding service status words

The service status may be accessed directly via the serial link. This method of accessing
service status will give the most complete picture of current and future service
requirements and will allow preventative maintenance activities to be scheduled.
A summary of the current pending service status is provided in response to the service
status command:
Command
The reply will be as follows:
B8J200880_D
300812671_002_C3
B8J200880_D - Maintenance
on page 106).
on page 105.
?
v
Page 90
Return the equipment or components
8
8
1
08/2021 - ©Edwards Limited
Bearing on-
cr

Advertisement

Table of Contents
loading

This manual is also suitable for:

Next930dNext1230h

Table of Contents