Edwards nEXT730D Instruction Manual page 40

Turbomolecular pumps
Table of Contents

Advertisement

Object name
Command
Normal speed setting !S856
?S856
Standby speed set-
!S857
ting
?S857
Temperature read-
?V859
ings
Link parameter read-
?V860
ings
Pump run hours
?V862
Temperature read-
?V865
ings 2
Factory settings
!S867
PIC software version
?S868
Speed control
!C869
Timer options
!S870
?S870
B8J200880_D
300812671_002_C3
B8J200880_D - Technical data
Parameter range
Factory set-
ting
50..100
80
-
-
55..100
70
-
-
0..100
-
0..100
0..500
-
0..300
0..15000
0..65535
-
-200..200
-
-200..200
-200..200
1
-
10
-
0
-
1
-
0
1
1
-
Page 40
Data type
Units
decimal
%
-
-
decimal
%
-
-
decimal
°C
decimal
°C
decimal
0.1 Volts
decimal
0.1 Amps
decimal
0.1 Watts
decimal
hours
decimal
°C
decimal
°C
decimal
°C
-
-
string
chars
decimal
-
-
-
decimal
-
-
-
Comments
Normal speed as a percentage of full
speed
-
Standby speed as a percentage of full
speed
-
Measured motor temperature
Measured motor controller temperature
Measured link voltage
Measured link current
Measured link power
Hours run by pump
Measured motor temperature
Measured motor controller temperature
Measured bearing temperature
Reset all configuration options and pa-
rameters to the factory settings
Boot loader software version number
(D396696XXX)
Set target speed to full speed
Set target speed to standby speed
Timer = disabled
Timer = enabled
Note that the timer is permanently ena-
bled on ramp-up.
08/2021 - ©Edwards Limited

Advertisement

Table of Contents
loading

This manual is also suitable for:

Next930dNext1230h

Table of Contents