Configure task and VoiceConsole
1. Set the following advanced parameter in Task config
barcodeport = bt_scan
2. Turn on Bluetooth on the device.
3. View the properties of the device and ensure Bluetooth is enabled. If it is not enabled, click
Edit this device and set Bluetooth Enabled to "enabled".
4. Select Pair this device with a peripheral.
5. For Pairing type select "Bluetooth Scanner".
6. For Connection Mode select "Device listens for peripheral connection".
7. Set Security to "Enabled" or "Disabled" as desired.
8. Scan the LnkB bar code created above to initiate pairing.
9. The 8670 scanner indicates a successful connection with the following indicators:
The LED on the scanner flashes green and a beep is sounded.
l
The LED on the Bluetooth module is solid blue.
l
Honeywell Granit 1911i Scanner
NOTE
Refer to the
Xenon/Granit User Guide
codes.
NOTE
The process below connects the peripheral using the Default profile. To use the Master
profile, set the following:
[HKEY_LOCAL_MACHINE\Software\Vocollect\NetworkD\RadioSettings]
TerminalRoleSRX=master
TerminalRoleOther=master
Device as Initiator
Configure Granit 1911i Scanner
The Granit 1911i scanner must be set to Host Reconnect Mode (the Granit 1911i will
l
attempt to connect to the device host, and if disconnected the device will manage the
reconnection).
The Granit 1911i must be configured to add termination characters (i.e., <CR><LF>).
l
1. Restore factory defaults by scanning the Remove Custom Defaults and Activate Defaults bar
codes.
2. Scan the Host Reconnect Mode bar code.