Table of Contents

Advertisement

EXAMPLE

You may run HyperTerminal.exe on the host computer to send serial commands to the 1564
scanner via RS-232, USB Virtual COM or BT SPP.
For the scanner to stop immediately –
D
For the scanner to resume working –
E
For the scanner to change the beeper to medium volume and beep –
#@101011<CR>
#@////<CR>
For the scanner to change the beeper to minimal volume and beep –
#@101010<CR>
#@////<CR>
For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) and
beep –
#@101001<CR>
#@////<CR>
For the scanner to change the beeper length to longest (for Good Read Beep only) and
beep –
#@101008<CR>
#@////<CR>
For the scanner to save the settings, send the serial command "#@109999" –
#@101011<CR>
#@109999<CR>
For the scanner to read the serial number and beep –
#@RDSN<CR>
#@////<CR>
For the scanner to beep for nine times –
#@BEEP,09<CR>
For the scanner's LED indicator to blink in red for nine times –
#@RLED,09<CR>
For the scanner's LED indicator to blink in green for nine times –
#@GLED,09<CR>
Appendix II
Host Serial Commands
Update
253