2.6.5 HID CHARACTER TRANSMIT MODE

By default, HID interface sends data to the host in batch. You may have the scanner read
the "By Character" barcode to process data one character at a time.

2.6.6 SPECIAL KEYBOARD FEATURE

By default, this interface employs special function codes (0x01 ~ 0x1F) defined in the
Keyboard Wedge Table. However, users may want to get rid of these special codes within
the barcodes to avoid data error. You can decide whether to apply the special keyboard
feature. For further details please refer to

2.6.7 USB HID VIA CRADLE AUTO-RECONNECTION

Users can decide whether to have the scanner automatically reconnect to a paired device
after disconnection, and the occasion for reconnecting.
Chapter 2
*Batch Processing
By Character
Keyboard Wedge
Table.
*Apply
Bypass
*Auto reconnect
immediately
Auto reconnect on
data scanned
Auto reconnect off
Update