1.5.5
Maximum and Minimum Flow (cont.)
bar
15cm
7
9.2
14
17.4
28
34.6
41
52.8
55
72.1
69
92.3
83
113.4
96
135.3
102
144.1
Maximum flow rates are based on 0.72 m/sec flow velocity for 15 cm through 25 cm diameter
pipes, and on 0.45 m/sec for 30 cm through 61 cm diameter pipes.
bar
15cm
7
0.5
14
0.9
28
1.7
41
2.6
55
3.6
69
4.6
83
5.7
96
6.8
102
7.2
Minimum flow rates are based on 36 m/sec flow velocity for 15 cm through 25 cm diameter pipes,
and on 27 m/sec for 30 cm through 61 cm diameter pipes.
Sentinel™ User's Manual
20cm
25cm
30cm
15.9
25.0
22.3
30.1
47.5
42.3
59.9
94.5
84.1
91.5
144.2
128.4
124.8
196.7
175.1
159.8
251.9
224.3
196.4
309.6
275.6
234.2
369.2
328.6
249.6
393.4
350.2
20cm
25cm
30cm
0.8
1.3
1.3
1.5
2.4
2.5
3.0
4.7
5.1
4.6
7.2
7.7
6.2
9.8
10.5
8.0
12.6
13.5
9.8
15.5
16.6
11.7
18.5
19.8
12.5
19.7
21.1
36cm
41cm
46cm
26.9
35.2
44.5
51.1
66.8
84.5
101.7
132.8
168.1
155.1
202.7
256.5
211.6
276.5
349.9
271.0
354.1
448.2
333.1
435.1
550.7
397.2
518.9
656.8
423.2
552.9
699.8
36cm
41cm
46cm
1.6
2.1
2.7
3.1
4.0
5.1
6.1
8.0
10.1
9.3
12.2
15.4
12.7
16.6
21.0
16.3
21.3
27.0
20.0
26.2
33.1
23.9
31.2
39.5
25.5
33.2
42.1
Chapter 1. Installation
51cm
61cm
55.3
80.0
105.0
151.9
208.9
302.1
318.8
461.0
434.8
628.9
556.9
805.5
684.3
989.8
816.1
1180.3
869.6
1257.8
51cm
61cm
3.3
4.8
6.3
9.1
12.6
18.2
19.2
27.7
26.1
37.8
33.5
48.4
41.2
59.5
49.1
71.0
52.3
75.6