Installation; Before Installation - Daikin VAM-FA8VE Technical Data Manual

Heat reclaim ventilation
Table of Contents

Advertisement

• HRV • VKM-GA(M)V1

9 Installation

HRV;Heat Reclaim Ventilation
Please read this installation manual carefully and install the unit properly to keep it at full capacity for a long time.
Please provide some necessary parts, for example round hoods, air suction/discharge grilles etc., before
the installation of the unit.
9.1

Before Installation

The accessories needed for installation must be retained in your custody until the installation work
is completed. Do not discard them!
After carrying in the unit, protect it with packing materials to prevent it from scratching until installation work
is done.
[1] Decide upon a line of transport.
[2] Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is
unavoidable, use a sling of soft material or protective plates together with a rope when lifting, to avoid
damage or scratches to the unit.
Hold the unit by the hanger brackets (4) when opening the crate and moving it, and do not lift it
holding on to any other part (especially the refrigerant piping, the drain piping, the water supply
piping, and the duct connecting flange).
9.1.1
Precautions
Be sure to instruct customers how to properly operate the unit (especially maintenance of air filter, and
operation procedure) by having them carry out operations themselves while looking at the manual.
Where the air contains high levels of salt such as that near the ocean and where voltage fluctuates
greatly such as that in factories. Also in vehicles or vessels.
9.1.2
Accessories
Check the following accessories are included with your unit.
Name Duct connecting
Quantity
Shape
Name
Quantity
Shape
9.1.3
Optional Accessories
This unit can be made a part of two different systems: as part of the combined operation system used
together with VRVIII SYSTEM Air Conditioners, and as the independent system using only the HRV. An
operating remote controller is required for this unit when using the unit as an independent system.
Select a suitable remote controller from below table according to customer request and technical
materials.
Table
Remote controller type
NOTE) 1
If you use the remote controller which is not listed in above table, please consult your dealer.
NOTE) 2
We recommend the remote controller "BRC1D527" especially when the unit is used as independent
system. Because it displays the ventilation mode and can be selected ventilation fan mode with the button.
When installing the unit, have ready the round shape hood, the air discharge grille and the air suction
grille, and other parts needed for the installation.
Consult your Daikin dealer when selecting optional accessories.
Be sure to check the type of R-410A refrigerant to be used before installing the unit. (Using an
incorrect refrigerant will prevent normal operation of the unit.)
For the installation of an outdoor unit, refer to the installation manual attached to the outdoor unit.
M4 tapping screw
flange
(For connecting duct)
4 pcs.
24 pcs.
50 type
80, 100 type M4×16
Refrigerant piping
Water supply piping
insulation cover
insulation cover
VKM-GAMV1:1 pc.
1 set
VKM-GAV1: 0 pc.
I.D.: φ35
I.D.: φ26
BRC1A62, BRC1D527
• HRV • Heat Reclaim Ventilation
Water supply piping
with strainer
VKM-GAMV1:1 pc.
VKM-GAV1: 0 pc.
M4×12
Sealing material
1 pc.
I.D.: φ15
Half-union joint
Flare nut
(Copper piping joint)
(Copper piping joint)
VKM-GAMV1:1 pc.
VKM-GAMV1:1 pc.
VKM-GAV1: 0 pc.
VKM-GAV1: 0 pc.
Clamp
(Other)
VKM-GAMV1: 8 pcs.

• Installation

VKM-GAV1: 6 pcs.
manual
• Operation
manual