7
Product Specification
1
7-2
Optional accessories
7-2-10 K-DGL100A, K-DGL150A, K-DGL200A, K-DGL250A: Air suction / discharge grill
7
Model name
Applicable model
Nominal pipe diameter (mm)
Noise reducing effect (dB)
Effective opening area (cm
Weight (kg)
Applications and features
• The grille can be installed at any location, using a duct.
• The grille effectively reduces the total heat exchanger noise transmitted from the duct.
Cautions
• Do not install the grille in a place of excessive high temperature.
• Do not install the grille in a place of much oil and smoke and of high humidity.
Pressure loss curve
K-DGL100A
25
20
15
10
5
0
K-DGL200A
30
25
20
15
10
5
0
78
• HRV • VAM-FA8VE
K-DGL100A
VAM150FA
φ 100
approx. 6
2
)
187
2.4
Supply air
Exhaust
air
100
200
3
Air flow rate (m
/h)
(HC0193)
Supply air
Exhaust
air
100
200
300
400
500
600
3
Air flow rate (m
/h)
(HC0239)
• HRV • Heat Reclaim Ventilation
K-DGL150A
K-DGL200A
VAM250FA
VAM500FA
VAM350FA
VAM650FA
φ 150
φ 200
approx. 6
approx. 11
257
333
3.3
4.5
K-DGL150A
25
20
15
10
5
0
100
K-DGL250A
25
20
15
10
5
0
200
K-DGL250A
VAM 800FA
VAM1000FA
VAM1500FA
VAM2000FA
φ 250
approx. 11
438
5.2
Supply air
Exhaust
air
200
300
400
3
Air flow rate (m
/h)
(HC0194)
Supply air
Exhaust
air
400
600
800
3
Air flow rate (m
/h)
(HC0240)