Daikin VAM-FA8VE Technical Data Manual page 196

Heat reclaim ventilation
Table of Contents

Advertisement

7
Product Specification
7 - 2 VKM-GAV1
7 - 2 - 5 Wiring diagram
2
VKM50,80,100GAV1
7
Indoor unit
A1P
Printed circuit board
A2P
Printed circuit board
C1•C2
Capacitor (M1F)
F1U
Fuse ( , 10A, 250V) (A1P)
F1U
Fuse ( , 5A, 250V) (A2P)
F1UT•F2UT Thermo switch
(152°C) (M1F, M2F built-in)
HAP
Light emitting diode
(service monitor-green) (A1P)
HAP
Light emitting diode
(service monitor-green) (A2P)
K1R~K3R
Magnetic relay (M1F) (A1P)
K4R~K6R
Magnetic relay (M2F) (A1P)
K7R
Magnetic relay (M1D) (A1P)
M1D
Motor (damper motor)
: Terminal block
,
: Connector
: Short circuit connector
: Terminal
: Field wiring
NOTES
1
In case of using central remote control, connect it to the unit in accordance with the attached instruction manual.
2
In case using wiring adapter, connect it to the unit in accordance with the attached installation manual.
3
When connecting the input wires from outside, fresh up control operation can be selected by remot control, in details, refer to the installation manual
attached the unit.
4
When connecting the input wires from outside, forced off or on/off control operation can be selected by remot control, in details, refer to the In case
of installation manual attached the unit.
5
Do not remove the short circuit connectors of X8A and X9A. The unit will not run if they are removed.
6
SS1 (A1P) has already been set to 'nor', at factory set. The unit will not run if the setting are changed.
7
Use copper conductors only.
194
• HRV • VKM-GAV1
Power supply
220-240V
~
50 Hz
Adapter PC board for wiring
(optional accessories)
Note 2
Note 6
Control box
M1F
M2F
R1T
R2T
R3T
R4T, R5T
S1Q
SS1
T1R
T2R
X1M
X2M
X3M
X17A, X19A Connector (relaying wire)
X20A
Y1E
• HRV • Heat Reclaim Ventilation
External output
terminals
Contact
capacity
AC220-240V
0.01~1.6A
Note 3
Input from
outside
Motor (supply air fan)
Motor (exhaust air fan)
Thermistor (indoor air)
Thermistor (outdoor air)
Thermistor (inlet air into coil)
Thermistor (liquid/gas pipe of coil)
Limit switch (damper motor)
Selector switch (for especially use) (A1P)
Transformer (220-240V/22V)
Transformer (220-240V/22V)
Terminal block (power supply)
Terminal block (control) (A1P)
Terminal block (control)
Connector (relaying wire)
Electronic expansion valve
Colors:
BLK:
Black
BLU:
Blue
GRN:
Green
ORG:
Orange
Note 4
Input from outside
Note 1
Transmission wiring,
central remote control unit
Wired remote control
(optional accessory)
Optional accessories
Wired remote control
SS1
Select switch (main/sub)
Adaptor PC board for wiring (KRP50-2)
Ry1
Magnetic relay (operation/stop)
Ry2
Magnetic relay (for humidifier operation)
Tes10
Terminal block (for external output)
Connector for optional parts
X11A
Connector (adapter power supply) (A1P)
X18A
Connector (wiring adapter for electrical
appendices) (A2P)
PNK:
Pink
RED:
Red
WHT: White
YLW:
Yellow
3D051311