Product Specification
7 - 1 VKM-GAMV1
7 - 1 - 6 Sound data
7 - 1 - 6 - 1 Sound pressure spectrum
VKM80GAMV1
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
NOTES
1
Over All (dB):
(B, G, N is already rectified)
2
Operating conditons:
Power source: Single phase 50Hz 220V
Model: VKM80GAMV1
Ventilation mode: total heat exhange
3
Measuring place:
Remark:
Operation noise is measured in an anechoic chamber.
The operation noise level becomes greater than this value depending on the operation
conditions, reflected sound, and peripheral noise.
Operation noise differs with operation and ambient conditions.
U-H: ultra-high, H: high, L: low
4
Location of microphone
1.5m
Measuring point
5
Operation noise differs with operation and ambient conditions.
VKM80GAMV1
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
NOTES
1
Over All (dB):
(B, G, N is already rectified)
2
Operating conditons:
Power source: Single phase 50Hz 240V
Model: VKM80GAMV1
Ventilation mode: total heat exhange
3
Measuring place:
Remark:
Operation noise is measured in an anechoic chamber.
The operation noise level becomes greater than this value depending on the operation
conditions, reflected sound, and peripheral noise.
Operation noise differs with operation and ambient conditions.
U-H: ultra-high, H: high, L: low
4
Location of microphone
1.5m
Measuring point
5
Operation noise differs with operation and ambient conditions.
• HRV • VKM-GAMV1
4D051292
Scale
Air flow rate
U-H
H
L
A
38.5
36
33
4D051305
Scale
Air flow rate
U-H
H
L
A
40
37.5
35.5
• HRV • Heat Reclaim Ventilation
VKM80GAMV1
Approximate
threshold hearing
for continuous
noise
Octave band center frequency (Hz)
NOTES
Scale
1
Over All (dB):
(B, G, N is already rectified)
2
Operating conditons:
Power source: Single phase 50Hz 230V
Model: VKM80GAMV1
Ventilation mode: total heat exhange
3
Measuring place:
Remark:
Operation noise is measured in an anechoic chamber.
The operation noise level becomes greater than this value depending on the operation
conditions, reflected sound, and peripheral noise.
Operation noise differs with operation and ambient conditions.
U-H: ultra-high, H: high, L: low
4
Location of microphone
1.5m
Measuring point
5
Operation noise differs with operation and ambient conditions.
4D051299
Air flow rate
U-H
H
L
A
39
37
34
2
7
177