Daikin VAM-FA8VE Technical Data Manual page 168

Heat reclaim ventilation
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS
Piping connection
Liquid
Gas
2
Water supply
Drain
7
Refrigerant control
Insulation material
Heat exchange system
Heat exchange element
Air Filter
Connection duct diameter
Operation mode
Standard
Accessories
Notes
166
• HRV • VKM-GAMV1
Type
Diameter
mm
Type
Diameter
mm
mm
mm
Cooling and heating capacities are based on the following conditions: Fan is based on High and
Ultra High. The figures in parenthesis indicate the heat reclaimed from the heat recovery ventilator.
Operation sound measured at 1.5m below the center of the unit is converted to that measured in
an anechoic chamber, built in accordance with JIS C1502 condition. The actual operation sound
The sound level at the air discharge port is about 8-11dB higher than the unit's operating sound.
For operation in a quiet room, it is required to take measures to lower the sound, for example install
Efficiency is measured under following condition: ratio of rated external static pressure has been
Feed clean water. If the supply water is hard water, use a water softener because of short life. Life
of humidifying element is about 3 years (4,000 hours, under the supply water conditions of
During the heating operation the freezing of the outdoor unit coil increases, heating capacity
decreases and the system goes into defrost operation. During defrost operation the fans of the
units continue driving (factory settings), the purpose of this is to maintain the amount of ventilation
When connecting with a VRV Heat Recovery outdoor unit, bring the RA (exhaust gas intake) of this
unit directly in from the ceiling. Connect to a BS unit identical to the VRV outdoor unit (master unit),
When connecting the indoor unit directly to the duct, always take the same system on the indoor
unit as with the outdoor unit. Perform group-linked operation and make the direct duct connection
settings from the remote controller. (Mode No. '17 (27)' -first code n° '5' - Second Code n° '6') Do
not connect to the outlet side of the indoor unit, depending on the fan strength and static pressure
• HRV • Heat Reclaim Ventilation
VKM80GAMV1
VKM100GAMV1
flare connection
6.4
flare connection
12.7
6.4
PT3/4 external thread
electronic expansion valve
Self-extinguishable urethane foam
Air to air cross flow total heat (sensible + latent heat) exchange
Specially processed non-flammable paper
Multidirectional fibrous fleeces
250
Heat exchange mode, bypass mode, fresh-up mode
Installation and operation manual
Duct connection flange
M4 tapping screw to connect duct
water supply piping with strainer
half union joint (copper piping joint)
flare nut (copper piping joint)
refrigerant piping insulation cover
water supply piping insulation cover
sealing material
When calculating the capacity as indoor units, use 5.6kW.
Cooling capacities are based on: indoor temperature: 27
Heating capacities are based on: indoor temperature: 20
Humidifying capacity is based on
varies depending on the surrounding conditions (near running unit
more than 2m soft duct near the air discharge grille
Air flow rate can be changed over to Low mode or High mode.
Normal amplitude, input, efficiency depend on the other above conditions
In case of holding full water in humidifier
OA: fresh air from outdoor, RA: return air from the room
The specifications, designs and information here are subject to change without notice
Temperature Exchange Efficiency is a mean value in cooling and heating
kept as follows: outdoor side to indoor side = 7 to 1
hardness: 150mg/l). Life of humidifying element is about 1 y
and humidification.
and use group-linked operation.
the unit might back up.
VKM50GAMV1
6.4
6.4
12.7
12.7
6.4
6.4
250
200
clamp