AT commands

DP (Remote Manager Phone Number)

Sets the Remote Manager phone number for the XBee device. This code must match the phone
number option in the SMS Configuration dialog.
See
Configure SMS messaging in Remote Manager
Range
-
Default
32075

HF (Health Metrics Reporting Frequency)

Reports the time between attempts to upload metrics. The time is measured in minutes. Metrics
which cannot be collected or reported at any particular time are skipped until the next attempt.
Parameter range
1 to 0xFFFF
Value
0x3c
Default
0x3c

HM (Health Metrics)

Sets the Health Metrics to report. This is a bit-mask of values. Each bit set in the mask represents a
metric which is reported to Remote Manager.
Parameter range
N/A
Bit
Description
0
Signal Strength.
Set bit 0 to enable reporting of signal strength metrics.
If available on your device the following metrics are reported:
Module Temperature in Celsius. This is reported to the "metrics/temperature" Data
1
Stream in Remote Manager for the devices.
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
Description
One hour.
"metrics/signal_strength": Uncached RSSI signal value. This is the same
n
value as reported by the
"metrics/signal_receive_power": Reference Signals Received Power (RSRP).
n
This is the same value as reported by the
"metrics/signal_receive_quality": Reference Signal Received Quality (RSRQ).
n
This is the same value as reported by the
Remote Manager commands
for more information.
DB command
with parameter 1, in dbM.
SW
command, in dBm.
SQ
command, in dB.