Ft (Flow Control Threshold); Ap (Api Enable); Ib (Cellular Component Baud Rate) - Digi XBee 3 Cellular LTE-M User Manual

Smart modem
Table of Contents

Advertisement

AT commands
Parameter range
0 - 0xFF
Default
0x0

FT (Flow Control Threshold)

Set or display the flow control threshold.
The device de-asserts CTS when FT bytes are in the UART receive buffer.
Parameter range
0x9D - 0x82D
Default
0x681

AP (API Enable)

Enables the frame-based application programming interface (API) mode.
The API mode setting. The device can format the RF packets it receives into API frames and send
them out the UART. When API is enabled the UART data must be formatted as API frames because
Transparent mode is disabled. See
Parameter range
0x00 - 0x05
Parameter
0x00
0x01
0x02
0x03
0x04
0x05
Default
0

IB (Cellular Component Baud Rate)

Note
Digi does not recommend using bypass mode. You should use
Sets the serial interface baud rate for communication between the XBee CPU and the cellular
component when in bypass mode. You can set bypass mode by setting the
configure the cellular modem to use the same baud rate (AT+IPR) prior to changing this setting.
Digi XBee® 3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
Modes
for more information.
Description
API disabled (operate in Transparent mode)
API enabled
API enabled (with escaped control characters)
N/A
MicroPython REPL
Bypass mode
Serial interfacing commands
USB Direct mode
instead.
AP command
to 5. You must
204