11.2.2 Error messages

Error
Transmission to
DAC failed
3121
5302
9116
9170
9180
132
Possible causes
Connection to the control
system cannot be estab-
lished
• Compressed air too low
• Compressed air not
connected
Seam program contour
data too large
Unknown pocket shape
No transfer plate
No technology point for
switching the transfer plate
Operating Instructions 806N-111/806N-121 - 04.0 - 12/2020
Troubleshooting
Remedy
• Deactivate the EMERGENCY
STOP devices  p. 53
• Notify technician
• Set the operating pressure
 p. 121
• Connect compressed air
 p. 120
• Select different seam program
 p. 75
• Install new seam program
• Select different seam program
 p. 75
• Install new seam program
Insert transfer plate  p. 46 and
reference machine again
Select different seam program
 p. 75