Lucent Technologies AP-3 User Manual page 308

Avaya ap-3 access point: connection guide
Hide thumbs Also See for AP-3:
Table of Contents

Advertisement

APS (Application Plus Server) 4.1 Users Guide
600021
308
Error Type
4 - Point of Interest
Module Type
601 - Auto_Init on reboot
Status Message
POI: APS:X25 is not running
Status Data 1
x.25 not running, Reboot_Init aborted
Effect
Auto_Init aborts, nothing starts , and there is no production.
Description
The X.25 link was checked and it is not running.
Resolution
1. Check the "enable on reboot" option in the x25 tool with the
following steps:
2. Log in as super user. Enter su
and enter the correct password.
3. Enter x25tool&
4. From the x25tool main menu choose
Options
Start X.25 automatically when booted
5. Reboot the system.
See ''Rebooting the Sun System'' on page 177.
The X.25 link should come up automatically.