Lucent Technologies AP-3 User Manual page 280

Avaya ap-3 access point: connection guide
Hide thumbs Also See for AP-3:
Table of Contents

Advertisement

APS (Application Plus Server) 4.1 Users Guide
523000
280
Error Type
2 - Error
Module Type
26 - IPC Library
Status Message
ERROR: Unable to create or Attach to IPC MSGQ.
Status Data 1
ERRNO=[Integer] RC=[Integer] MQ_ID=[Integer] MODE=[Integer]
Effect
Service will be affected.
Description
The IPC library was unable to attach or create the requested IPC
subsystem. ERRNO provides further information.
Resolution
1. Restart the script. See ''Starting a Single Script'' on page 123 or
''Starting a Script Group or Application Manually'' on page 122.
2. If restarting the script does not correct the situation, escalate this
problem to the next level of support.