Lucent Technologies AP-3 User Manual page 313

Avaya ap-3 access point: connection guide
Hide thumbs Also See for AP-3:
Table of Contents

Advertisement

600026
101-1830-001
Issue 1.0
Error Type
4 - Point of Interest
Module Type
601 - Auto_Init on reboot
Status Message
POI: APS: application manager not running
Status Data 1
Aborting Init_app_mgr
Effect
No scripts start, no production.
Description
The application manager (issg_appmgr) process is not running.
Resolution
1. Enter cd /export/home0/issg/issg_main/issg_lib/libappmgr
and make sure that the file issg_appmgr is there and that the
permissions are correct.
2. Then enter
cd /export/home0/issg/issg_main/issg_lib/libautoreb
3. Enter Init_app_mgr to try running it from the command line.
4. Also check the status log for other errors.
5. If the previous steps don't solve the problem, escalate this
problem to the next level of support.