HYDRAULIC SYSTEM
11. Remove the seat retainer rod (Fig. 156).
12. Remove the hydrostatic pump from the frame (Fig.
4
157).
13. For service work on the pump refer to the Hydro
Gear BDP-10A (PG)/16A/21L Service Manual, form
#492-4789.
4-4
Fig 156
PICT-0092a
Fig 157
PICT-0093a rev
Hydrostatic Pump Installation
1. Place the hydrostatic pump into the frame (Fig. 158).
Fig 158
2. Install the bolt, washer and nut that retain the
tracking link rod to the hydro control arm (Fig. 159).
Tighten hardware.
Fig 159
Z Master Z400 Service Manual
PICT-0093a
PICT-0082a