1. Lift the back of the machine so the rear tires (left and
right) are off the ground. Place jack stands under
the rear frame to support the unit. Remove the rear
wheel from side of machine being flow tested; in this
case, the left rear wheel is removed (Fig. 203).
Note: Be careful not to place jack stands near
any moving parts or areas not capable of
supporting the weight of the machine.
Fig 203
2. Clean all dirt and debris away from the hydraulic line
fittings. Remove the hydraulic lines. Make sure you
mark which hydraulic line goes to which fitting on
the wheel motor. If the hydraulic lines are reversed,
the motor will operate in the opposite direction (Fig.
204).
Fig 204
Z Master Z400 Service Manual
HYDRAULIC SYSTEM
3. Loosen hydraulic lines at the pump to obtain enough
clearance to connect flow tester to the hydrostatic
high pressure lines (Fig. 205). Retighten fittings at
the pump.
4. Connect the hydraulic hose fittings to the hydraulic
flow tester and tighten the fittings (Fig. 206). If the
PICT-0020a
flow tester is not bidirectional, make sure to connect
hoses correctly.
PICT-0021a
Fig 205
PICT-0022a
Fig 206
PICT-0023a
4
4-19