AUMA ACE C 01.2 Profinet Series Manual page 66

Actuator controls device integration
Hide thumbs Also See for ACE C 01.2 Profinet Series:
Table of Contents

Advertisement

Appendix
ID
Type
Parameters
PRM
4772
I32
Min. temp. MWG
PRM
5062
U32
Max. vibration
Table 83: Device configuration > Operational info
ID
Type
Parameters
Data length = 82 bytes
PRM
163
U32
Motor running time
PRM
5225
U32
Max. running time /h
PRM
5067
U32
Operating hours
PRM
164
U32
Motor starts
PRM
5224
U32
Max. starts/h
PRM
5212
U32
Mean torque value
PRM
170
U32
No. thermal faults
PRM
175
U32
Torque fault CLOSE
PRM
171
U32
Torque fault OPEN
PRM
4697
U32
Wrn torque CLOSE
PRM
4696
U32
Wrn torque OPEN
PRM
5400
U32
Wrn torque OP+CL
PRM
172
U32
Limit trip CLOSED
PRM
174
U32
Limit trip OPEN
PRM
166
U32
Torque trip CLOSE
PRM
173
U32
Torque trip OPEN
PRM
168
U32
On time warning 1
PRM
167
U32
On time warning 2
PRM
165
U32
No. system starts
PRM
4757
I32
Max. temp. controls
66
Ac-
Default
Setting value
cess
R
Min = 100 [°C]
Max = +150 [°C]
R
Min = 0 [g]
Max = 4294967295 [g]
Ac-
Default
Setting value
cess
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0 [%]
Max = 4294967295 [%]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 100 [°C]
Max = +150 [°C]
Actuator controls
AC 01.2/ACExC 01.2 Profinet
Explanation
Minimum temperature of MWG
Maximum actuator vibration
Explanation
Motor running time
Operating hours counter: num-
ber of hours during which con-
trols are supplied with power
Number of motor starts
Number of thermal faults
Number torque faults CLOSE
Number of torque faults OPEN
Number of torque wanrings
CLOSE
Number of torque warnings
OPEN
Number of torque warnings
OPEN+CLOSE
Number of limit switch CLOSED
trippings
Number of limit switch OPEN
trippings
Number of torque switch
CLOSE trippings
Number of torque switch OPEN
trippings
Total number of all time intervals
during which an on time warning
was indicated.
Max. time span during which an
on time warning was indicated.
Number of system starts
Maximum temperature of con-
trols

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac 01.2 profinet

Table of Contents