AUMA ACE C 01.2 Profinet Series Manual page 65

Actuator controls device integration
Hide thumbs Also See for ACE C 01.2 Profinet Series:
Table of Contents

Advertisement

Actuator controls
AC 01.2/ACExC 01.2 Profinet
Table 82: Asset Management > Operational info total
ID
Type
Parameters
Data length = 80 bytes
PRM
495
MMSS01
Motor running time
PRM
5227
MMSS01
Max. running time/h
PRM
5068
MMSS01
Operating hours
PRM
496
U32
Motor starts
PRM
5226
U32
Max. starts/h
PRM
5213
U32
Mean torque value
PRM
503
U32
No. thermal faults
PRM
501
U32
Torque fault CLOSE
PRM
502
U32
Torque fault OPEN
PRM
4704
U32
Wrn torque CLOSE
PRM
4703
U32
Wrn torque OPEN
PRM
5401
U32
Wrn torque OP+CL
PRM
498
U32
Limit trip CLOSE
PRM
500
U32
Limit trip OPEN
PRM
497
U32
Torque trip CLOSE
PRM
499
U32
Torque trip OPEN
PRM
505
U32
On time warning 1
PRM
506
U32
On time warning 2
PRM
507
U32
No. system starts
PRM
4765
I32
Max. temp. controls
PRM
4766
I32
Min. temp. controls
PRM
4771
I32
Max. temp. MWG
Ac-
Default
Setting value
cess
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0
Max = 4294967295
R
Min = 0 [%]
Max = 4294967295 [%]
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0
Max = 4294967295
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0 [s]
Max = 4294967295 [s]
R
Min = 0
Max = 4294967295
R
Min = 100 [°C]
Max = +150 [°C]
R
Min = 100 [°C]
Max = +150 [°C]
R
Min = 100 [°C]
Max = +150 [°C]
Appendix
Explanation
Motor running time throughout
the lifetime
Operating hours counter: num-
ber of hours during which con-
trols are supplied with power
Number of motor starts
throughout the lifetime
Number of thermal faults
throughout the lifetime
Number torque faults CLOSE
throughout the lifetime
Number of torque faults OPEN
throughout the lifetime
Number of torque warnings
OPEN+CLOSE during the life-
time
Number of torque warnings
OPEN+CLOSE during the life-
time
Number of torque warnings
OPEN+CLOSE during the life-
time
Number of limit switch CLOSE
trippings throughout the lifetime
Number of limit switch OPEN
trippings throughout the lifetime
Number of torque switch
CLOSE trippings throughout the
lifetime
Number of torque switch OPEN
trippings throughout the lifetime
Total number of all time intervals
throughout the lifetime during
which an on time warning was
indicated.
Max. time span during which an
on time warning was indicated.
Number of system starts
throughout the lifetime
Maximum temperature of con-
trols
Minimum temperature of con-
trols
Maximum temperature of MWG
65