Xerox DocuPrint 96 Message Manual page 37

Laser printing system
Hide thumbs Also See for DocuPrint 96:
Table of Contents

Advertisement

XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE
HP8250
Fatal protocol violation detected
Commands used violate the higher-level software protocols used to
communicate between the DocuPrint 96/DocuPrint 96MX LPS and
the host. The host will be advised to restart communication with the
printer. No data should be lost in this process.
Action
None.
HP9200
Interface failure: unable to receive data
A hardware error has occurred. The system is unable to recover lost
data. The job will abort and the interface will go offline.
Action
1. Resend the job.
2. If the error continues, contact your systems specialist or Xerox
Customer Service.
HP9210
Interface failure: failed to go offline
HIP is unable to post the offline status to the XPAF host computer.
Action
None.
HP9400
HostCLR not received. See host for reason
The HIP DIAGNOSTIC command for interactive diagnostics was
entered. The system failed Test 1: HOSTCLR control line not
verified.
Action
1. Wait until the diagnostic test is terminated or completed.
2. Contact your systems specialist or Xerox Customer Service and
give information appearing on the 871-CM display.
HP9410
Data to host transfer error. See host for reason
The HIP DIAGNOSTIC command was entered. The system failed
Test 2: unable to send a command on OEMI and in turn read the
printer status. The system is terminating the diagnostic test.
Action
1. Inspect the 871-CM display (the "host" referred to in message)
to learn the nature of the failure.
2. Contact Xerox Customer Service and give information
appearing on the 871-CM display.