Xerox DocuPrint 96 Message Manual page 98

Laser printing system
Hide thumbs Also See for DocuPrint 96:
Table of Contents

Advertisement

OSS (OPERATING SYSTEM SOFTWARE) MESSAGES
6-20
OS1262
Sysgen paper size out of range
If a paper size statement is not included in the JDL, the system will
use the values specified at SYSGEN. This message indicates that
the SYSGEN value is not supported by the IOT.
Action
Perform a MINI SYSGEN and correct the default paper size.
OS1263
Form paper size out of range: xxxxxx.xxx
Paper size for form specified in the JSL is not supported by the IOT.
Action
Contact your systems specialist.
OS1264
Barcode sequence mismatch
The IOT detected a sequence number other than the one expected.
Action
Check the job, correct the reason for the mismatch and rerun.
OS1265
Printer status request already in progress
A previous request for printer status is still being processed.
Action
None.
OS1266
A Barcode was specified, none found
The IOT did not detect a barcode where one was expected.
Action
Check Read Head alignment, bar code programming or continue job
in BAR OFF mode.
OS1267
ESS didn't confirm duplex hint
A sheet abort request was sent to the ESS from the IOT because the
ESS did not confirm a hint for the second side of a sheet already
committed to the paper path.
Action
None.
OS1268
Bar Align: sheet delivered. Seq1 = nn, Seq2 = nn
Sheets with sequence numbers have been read and delivered with
the printer operating in the bar align mode. Seq1 - front side, Seq2 -
back side.
Action
None.
OS1269
Bar Align: sheet delivered
Sheets were delivered but no sequence numbers were read with the
printer operating in the bar align mode.
Action
None.
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE