Resolution; Triggering - Keysight N9912A User Manual

Fieldfox analyzer
Hide thumbs Also See for N9912A:
Table of Contents

Advertisement

You can also use Run / Hold +/- to toggle between Single and Continuous.

Resolution

Resolution is the number of individual acquisitions that occur in the USB Power
Sensor. This data is read by the FieldFox and plotted across the X-axis to form a
trace. More data points increases measurement resolution. However, more data
points requires more time to acquire, query, and plot.
How to set Resolution
 Press Sweep 3
 Then
 Then choose from the following:

Triggering

For pulse measurements, a trigger signal refers to the event that causes the USB
Peak Power Sensor to initiate measurement acquisition. It does NOT refer to
triggering the FieldFox.
Trigger settings can be used with ALL pulse measurements unless stated otherwise.
A
USB Power Sensor when it is waiting for a pulse signal at the RF Input (Internal) or a
TTL signal at the USB Sensor External Trigger input.
How to make Trigger settings
 Press Sweep 3
 Then
 Then
 Then choose from the following:
Trigger Edge
This setting determines which edge of a trigger signal initiates data acquisition.
134
Automatically sets Continuous OFF and causes the FieldFox to query
Single
o
the USB Power Sensor ONCE, then hold for the next Single key press.
annotated in the upper left corner of the display.
Queries the USB Power Sensor whenever a valid trigger signal is
Continuous
o
present. This is the typical setting when battery power is not critical.
Resolution
240 data points.
Low
o
1000 data points.
Medium
o
Calculated value - approximately 8000 data points.
High
o
message on the FieldFox screen is posted on behalf of the
Waiting for Trigger
Trigger
Trig Type
The USB Power Sensor acquires data without waiting for a trigger.
Freerun
o
This mode is NOT supported for Trace Graph measurements.
The USB Power Sensor acquires data when a valid pulse signal is
Internal
o
detected at the RF input. The following Trigger settings determine the validity of
the trigger signal.
The USB Power Sensor acquires data when a valid TTL signal is
External
o
detected at the USB Power Sensor external trigger input.
Hold
is
FieldFox User's Guide