When the table edits are complete
 Press
 Press
 Press
About the Antenna/Cable header fields
 Description: Enter a description for the antenna or cable correction table. This is
 Antenna Unit: Units in which the measurement will be displayed. Select NONE
 Freq Interpolation: Set to LINear and can NOT be edited.
About the Freq/Value pairs
 Positive Values are interpreted as LOSS for both Cable Loss and Antenna Gain
 When one Freq/Value pair is entered, that correction value is applied to the entire
 When two or more Freq/Value pairs are entered, the data points between the
About Antenna and Cable files
 Cable files are saved and recalled from the Cables folder.
 Antenna files are saved and recalled from the Antenna folder.
 If the folder does not already exist on a USB or SD card, it is created automatically
 All SA Mode Antenna and Cable files are saved and recalled as *.csv files, which
 The FieldFox can also read *.ANT (Antenna) files that were created from older
 Data Link does NOT support the SA Mode cable or antenna (*.csv or *.ANT) files.
SA (Spectrum Analyzer) Mode
Remove the selected Freq/Value pair from the table.
Delete Line
o
then
Clear All
Yes
o
header information to default settings.
to closes the Antenna/Cable Editor.
Done
or
Save Antenna
Storage Device. Enter a filename using the FieldFox labeler (learn how on page
162). Learn more about Antenna and Cable files below.
or
Recall Antenna
specified Storage Device.
Changes the device used to save or recall files. Choose from
Storage Device
Internal (default setting), USB (must be connected) or SD card. This is a different
setting from the Save/Recall Storage Device setting.
NOT the filename used to save the file.
(default setting) to select from standard SA Units on the Scale menu. Learn how
on page 72.
Choose from: dB μV/m - (dB micro Volts per meter), dB μA/m - (dB micro Amps
per meter), dBG (gauss), dBpT (tesla).
Factor.
displayed frequency span.
lowest and highest frequencies are corrected. Linear interpolation is applied
between frequencies when necessary.
before storing the file.
allows them to also be read by spreadsheet programs.
Keysight Spectrum Analyzers.
Learn more about Data Link software at:
Remove all Freq/Value pairs from the table and resets
to saves your changes to the specified
Save Cable
to load an Antenna or Cable file from the
Recall Cable
www.keysight.com/find/fieldfoxsupport