7. After the rebuild is complete, on the menu screen, enter "1" and then press the [Enter]
key to check the status of the software RAID1.
Confirm that the status of the software RAID1 is normal (Array Status is "OPTIMAL"
and the HDD on either drive bay is "ONLINE") as shown below.
Show the status
Array Status:
HDD#2:
HDD#1:
Press Enter:
8. Press the [Enter] key to go back to the menu screen of the software RAID1 construction
utility.
9. On the menu screen, enter "5" and then press the [Enter] key to exit the software
RAID1 construction utility.
10.Remove the software RAID1 construction utility "Software RAID1 For Windows(R)"
from the DVD drive. Then press the power switch for four seconds or more to shut
down the power for the Equipment.
If you disconnected any external storage devices at Step 2, reconnect them to the
Equipment.
11.Turn on the power for the Equipment. After the OS starts up, confirm that both HDDs
are working properly on the hardware status screen.
Hardware Status Window
OPTIMAL
ONLINE
ONLINE
10-13
10. SOFTWARE RAID1