CHAPTER 1 GETTING STARTED

1.1

Scope

This manual describes the operation and adjustment procedures required in the operator's
daily operation of the Hitachi FA Computer HF-W2000 Model 35/30 (the "Equipment").
After opening the product package, make sure that all items are supplied and free of
damage. Check carefully to see if all components are delivered, according to the Packing
List. Contact your distributor in the event of any shortage or damage.
Please refer to the following manuals for software:
 HF-W2000 Model 35/30 Setup Guide (Manual No. WIN-63-0086)
 HF-W2000 Model 35/30 RAS Features Manual (Manual No. WIN-63-0085)
1.2

Installation Environment

1.2.1 Environmental conditions

When no commercial device is mounted in the extended slots of the Equipment, use the
Equipment under the environmental conditions shown in the following table. When a
commercial device is mounted in any of the said extended slots, follow the environmental
specifications for such a device.
Item
Ambient
temperature
Temperature gradient
Humidity
Humidity gradient
Dust
Corrosive gas
Vibration
Physical
shock
Power supply voltage
Power supply frequency
Power supply noise
Electrostatic
discharge
Insulation resistance
Dielectric strength
Momentary power outage
Altitude
*JEITA:Japan Electronics and Information Technology Industries Association
Specifications
Operating or idle 5 to 40 C for altitudes up to 1000 m
5 to 35 C for altitudes more than 1000 m up to 2000 m
-10 to 60 C
Inventory
±10 K/h or less
20 to 80 % RH, non-condensing
10 % RH/h or less
0.3 mg/m
non-conductive*
JEITA IT-1004A class A (at temperature 25 C,
humidity 50 % RH)*
5.9 m/s
Operating or idle 19.6 m/s
Not powered
98 m/s
AC 100 to 240 V with tolerance of ±10 %
(input waveform supports only a sine wave)
50/60 Hz with tolerance of 3 Hz
2.0 kV (fast transient/burst waveform)
Contact 4 kV
Air
8 kV
DC 500 V, 20 M
AC 1.5 kV, 1 minute
20 ms or less
2000 m or less
3
or less (JEITA IT-1004A class B),
2
(10 Hz, 5 s, excluding DVD)
2
2